Laserfiche WebLink
SAN JOAQUIN COUNTY <br />qVIRONMENTAL HEALTH DEPARTMENT 14. <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: vwwv.sogov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />V IPA(AcPe <br />6 30ru <br />Designated Operator: ` L <br />Inspection <br />Da <br />1 o °1 <br />Facility address: �/�% /� (,,� <br />0 , 6bV�r-� "" /� � � �I �'� <br />UST # <br />Product <br />acility Contact <br />M Ide- 6 11 q <br />Title: Phone: <br />-1 -8753 <br />Monitoring Panel: <br />Piping system: <br />ressurized ❑ Suction ❑ Gravity <br />Overfill prevention: <br />Mechanical ❑ Audible/visual <br />inspection type: Violations: <br />%LMoutine onitoring Certification ❑ Installation ❑ Other: 1-RDetect ❑ M2-RPrev ❑ M-3 Both <br />VIOLATION(S) HSC=California Health & Safety Code; C R=California Code of Regulations V R <br /># Code Section V <br />V=Violation; RV=Re eat Violation <br />1 <br />HSC 25284 <br />Permit to operate <br />2 <br />CCR 2637 <br />Secondary containment test performed -17 <br />3 <br />CCR 2711 b & c <br />Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br />4 <br />HSC 25292.2 <br />Certification of financial responsibility and CFO letter <br />5 <br />CCR 2632 b <br />Monitoring Program(Monitoring & Response Plan is current and approved by the local agency. <br />6 <br />CCR 2712 i <br />Monitoring Ian is onsite. <br />7 <br />CCR 2712 b <br />Maintenance & monitoring records M1 <br />8 <br />CCR 2643 d <br />Daily monitoring of suction piping (pre -January, 1, 1984 <br />9 <br />HSC 25292.1 <br />UST system isoperated to prevent unauthorized release <br />10 <br />CCR 2632 (c)(2) <br />UST monitoring system is present M1) <br />11 <br />CCR 2630 d <br />UST system monitoring equipment is properly located to detect a leak M1 <br />12 <br />HSC 25291 b <br />UST system monitoring equipment isoperational M1) <br />13 <br />CCR 2636 1 <br />Continuous monitoring system for underground piping & UDC is present M1 <br />14 <br />CCR 2631 a <br />Primary containment is product tight <br />15 <br />HSC 25291(a)(2)—Secondary <br />containment for UST is tight <br />16 <br />CCR 2636 (c)(1) <br />All releases in secondary pipingflow to a collection sum <br />17 <br />HSC 25291 <br />Line leak detectors are installed M1 <br />18 <br />CCR 2635 (b)(1) <br />Spill container (M2) <br />19 <br />CCR 2635 (b)(2) <br />Overfill prevention system M2 <br />20 <br />CCR 2636 (a) <br />Conventional suction piping shall have continuous monitoring & 20 containment <br />21 <br />HSC 25291 (e) <br />Water in 20 containment analyzed & properly disposed of <br />22 <br />CCR 2650 <br />Recording/reporting of unauthorized releases M1 <br />23 <br />CCR 2715 <br />Designated Operator: a Statement from UST owner; (c -e) Monthly inspection; Employee training <br />24 <br />CCR 2638 a <br />Annual monitoring certification <br />25 <br />CCR 2638 a <br />Annual line leak detector test M1 <br />26 <br />HSC 25284.2 <br />Annuals ill containment testing <br />27 <br />CCR 2636 4 <br />Annual line tightness test M1 <br />28 <br />CCR 2661 <br />Repair for tank/piping has had tightness test (M2) <br />29 <br />CCR 2643 a <br />Biennial tightness test of gravity pipingre-Janus 1, 1984 <br />30 <br />CCR 2643 d <br />Triennial line test for conventional suction piping (pre -Janus 1, 1984) (M1) <br />31 <br />HSC 25292.5 <br />Double walls stem located within 1000' of public well-ELD <br />32 <br />CCR 2661 <br />Permit to repair UST system <br />33 <br />HSC 25286 a <br />Permit to alter monitoring system <br />34 <br />HSC 25298 b <br />Permit to temporarily close UST system <br />35 <br />HSC 25298 c <br />Permit to close UST system <br />36 <br />HSC 25299 <br />a 9 2 <br />Disabling leak detection devices <br />37 <br />HSC 25298 a <br />Illegal abandonment of UST system <br />38 <br />Other: <br />EHD <br />SPECTOR:%� <br />IC`, <br />� <br />PHONE: �� "I <br />0 <br />tics stem: UIC <br />❑ es >_20 people/day <br />❑ Res other than sanitary waste <br />Other dis osa thods: <br />❑ Dry wells/Fren Drains <br />RECEIVED Y: <br />TITLE: <br />C.EW.I' <br />EHD 23-02-002 REV 8/08 <br />