My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2017-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 8:53:41 AM
Creation date
6/23/2020 6:54:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2017-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S y, <br />MONITORING SYSTEM CERTIFICATI <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of at o <br />4 18 <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be re ared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provide tMEMAp . LTH <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. DEPARTMENT <br />A. General Information <br />Facility Name: Valley Pacific Petroleum <br />Site Address: 1501 West Charter Way City: <br />Facility Contact Person: Mike Eliason <br />Make/Model of Monitoring System: Veeder Root TLS -350 Plus <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Bldg. No.: N/A <br />Stockton, CA Zip: 95206 <br />Contact Phone No.: (209) 993-8793 <br />Date of Testing/Servicing: 01/17/18 <br />Tank ID: T-1 87 <br />Tank ID: T-2 Diesel <br />® In -Tank Gauging Probe. <br />Model: VR -Mag -Plus <br />® In -Tank Gauging Probe. Model: VR -Mag -Plus <br />® Annular Space or Vault Sensor. <br />Model: VR -420 <br />® Annular Space or Vault Sensor. <br />Model: VR -420 <br />® Piping Sump / Trench Sensor(s). <br />Model: VR -208 <br />® Piping Sump / Trench Sensor(s). <br />Model: VR -208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: MLD -STP <br />® Mechanical Line Leak Detector. <br />Model: LD -2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: OPW Flapper Valve <br />® Tank Overfill / High -Level Sensor. <br />Model: OPW Flapper Valve <br />ElOther (specify equipment type and model in Section E on Page 2). <br />® Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: #1-2 <br />Dispenser ID: #3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: N/A <br />❑ Dispenser Containment Sensor(s). <br />Model: N/A <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: #5-6 <br />Dispenser ID: #7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: N/A <br />❑ Dispenser Containment Sensor(s). <br />Model: N/A <br />® Shear Valve(s). <br />®Shear Valve(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: #7 Satellite <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: N/A <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): RICHARD THOMAS Signature:/ <br />Certification No.: B34022 License. No.: 803616 <br />Testing Company Name: CGRS, Inc. Phone No.: 916-991-1100 <br />Testing Company Address: 5444 Dry Creek Rd. Sacramento, CA 95838 Date of Testing/Servicing: 01/17/18 <br />UN -036 — www.unidocs.org Rev. 01/17/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.