My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:46:51 PM
Creation date
6/23/2020 6:54:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232257_205 W LOCKEFORD_2004-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br />Test Method By: • Manufacturer O Industry Standard O Professional Engr. O Other (see below) <br />Test Method Uses: O Pressure • Vacuum o Hydrostatic o Other (see below) <br />Measuring Equipment Used: Vacuum Gauge (range 0 to 30 inches Hg) <br />Description <br />Tank i#7 <br />Tank 82 <br />Product stored <br />Gasoline - 87 <br />Gasoline - 89 <br />Tank manufacturer <br />Xerxes <br />Xerxes <br />Tank material <br />FRP <br />FRP <br />Tank capacity (US gallons) <br />10,000 <br />10,000 <br />Is this a multi -compartment tank? <br />No <br />No <br />Dry or Brine filled annular? <br />Dry <br />Dry <br />Monitoring system show normal annular? <br />Yes <br />Yes <br />Is water table above tank bottom? <br />Unknown <br />Unknown <br />Was sensor removed for testing? <br />No <br />No <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />Tank ##3 <br />Gasoline - 91 <br />Xeres <br />FRP <br />8,000 <br />No <br />Dry <br />Yes <br />Unknown <br />No <br />N/A <br />Wait time for vacuum to stabilize (hr:min) <br />0:10 <br />0:10 <br />0:10 <br />Test start time <br />9:08 AM <br />9:59 AM <br />9:34 AM <br />Initial vacuum (inches Hg) <br />10.0 <br />10.0 <br />10.0 <br />Test end time <br />10:08 AM <br />10:59 AM <br />10:34 AM <br />Final vacuum (inches Hg) <br />10.0 <br />10.0 <br />10.0 <br />Test duration (hr:min) <br />Change in vacuum (inches Hg) <br />Pass/Fail threshold (inches Hg / hour) <br />1:00 <br />0.0 <br />2.0 <br />1:00 <br />0.0 <br />2.0 <br />1:00 <br />0.0 <br />2.0 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />© 2006 Walton Engineering, Inc. <br />