COMPLIANCE INFO_2008-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:52:27 PM
Creation date
6/23/2020 6:54:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232257_205 W LOCKEFORD_2008-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL WILL CONTAINER TESD REPORT <br />TEST DATE: <br />Al. FACILITY <br />Name Quik Stop Market #148 <br />Address 205 W. Lockeford Street, Lodi, CA 95240 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />►ugust 6, 2009 <br />A2. OWNER <br />Name Quik Stop Markets, Inc. <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone# 510-657-8500 <br />Contact Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />August 3, 2009 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Aris Cacapit <br />contact <br />Richard Walton <br />Phone # <br />209-468-3439 <br />Phone # <br />916-825-3203 <br />K. SPILL CONTAINER TEST RESULTS <br />Measu <br />ent Used: Caldwell System ZUU1 / Walton <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inches) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (t 0.000 inches) <br />Pass/Fail threshold (0.005 inches / 1A Hr.) <br />TEST RESULT <br />L. COMMENTS: <br />The 91 SC failed at the bottom seam. <br />1 <br />Gasoline - 87 <br />5 <br />OPW <br />14.00 <br />Yes <br />No <br />Dry <br />Entire <br />12.50 <br />0:10 <br />10:47 <br />11:17 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />2 <br />Gasoline - 89 <br />5 <br />OPW <br />13.00 <br />Yes <br />No <br />Dry <br />Entire <br />11.50 <br />0:10 <br />10:14 <br />10:44 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />(Level mange Inaic <br />3 <br />Gasoline - 91 <br />5 <br />OPW <br />13.00 <br />Yes <br />No <br />Dry <br />Entire <br />11.50 <br />0:10 <br />11:20 <br />11:25 <br />0:05 <br />0.125 <br />0.005 <br />FAIL <br />, �y WALTON <br />&A5( <br />Signature: ENGINEERING, INC. <br />Technician: Bruce N. Stewart / A31131 5249892 -UT Date: August 6, 2009 <br />