Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.oralehdlunitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />FacilityFadiity <br />Name: Quik Stop Market #148 <br />,�dr�: 205 W. Lockeford St. Lodi, CA <br />Inspection <br />Dom: Sep 21, 2012 <br />Facility <br />Contact: Mike Karvelot <br />Title: <br />Director of Env. Affairs <br />p a� <br />rl) <br />l8 657-8500 <br />Inspection <br />Type: <br />C Routine XMonitoring System <br />Certification D installation C Complaint- ID# DlOther 91 Leak Detector <br />(Authority HSC 25289) do+� <br />Consent for. KInspertion XSampling XPhotos Granted by: - Titie: <br />Monitoring <br />Panel: Glibarc0 EMCn <br />System xPressurized 1 SM. - Gravity <br />r <br />thil <br />P vention: XMechanical r I Audiblelvisual <br />UST <br />- Product -- <br />_ 1 _ <br />-- 87-odan6 -- <br />2 <br />- 89 -octane - <br />3 <br />--91-octane <br />------- <br />--- ------- <br />----------- - <br />------- <br />------t_- <br />--- <br />— - <br />Desi <br />na <br />Ope atom Ryan Powell <br />CC <br />`Da3-14-13 <br />Violations: XM1-Release Detection C M2 -Release Prevention r-, M3 - Both <br />°ecnne� Jessie Wadkins ce <br />`Dai : 5-12-13 ManufacturersTraining: OPW 10-2-12; VMI 2-9-14 <br />VIOLATIONS <br /># I Cl C2 M Code Section <br />HSC = California Health and Safety Code; CCR = Califomia Code of Regulatims <br />C1 = Class 1 violation; C2 = Gass 2 violation• M =Minor violation <br />File Review <br />101 <br />HSC 25284 <br />No permit to operate <br />102 <br />HSC 25404.5 <br />Annual operating fees not paid <br />103 <br />HSC 25284(a)(3) <br />Pio written agreement between the person that the operating permit was issued to. and the tank operator to <br />monitor the tanks stem <br />104 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 <br />CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 <br />CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 <br />CCR 2632(d) 1)(C) <br />Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 <br />CCR 2637 <br />Secondary containment (a) test not performed; (e) test report not submitted within 30 days; (1) fest notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 <br />CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 x HSC 25291 (0 <br />Annual line teak detector test not performed (Mt) <br />111 <br />HSC 25284.2 <br />Annual spill containment testing not performed <br />112 <br />CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (Ally <br />113 <br />CCR 2715(s) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 <br />CCR 2715(b) <br />Designated operator does not possess a current IGG CA UST System Operator certification <br />115 <br />CCR 2660(k) <br />Repair for tank or piping not tested for tightness atter completion of the repair pursuant to (M2) <br />Dermit conditions <br />116 <br />HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />118 <br />HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 <br />HSC 25298(b) <br />Permit to temporarily dose UST system not obtained <br />120 <br />HSC 25298(c) <br />Permit to close UST system not obtained <br />On SHO Records <br />201 <br />CCR 2712(b) <br />Maintenance & mon(todng records not maintained 3 years, cathodic protection records for 6'Y. years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records Include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis perfomred a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations or other test results 6 results of inventory readings and reconciliations <br />202 <br />CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Aris Cacapit (209) 468-3453 <br />EHD 23-02 Rev 09/01/11 Page 1 UST INSPECTION REPORT <br />