Laserfiche WebLink
ANNUAL <br />ILL CONTAINER TEAN REPORT <br />TEST DATE: Au ust 3, 2012 <br />Al. FACILITY <br />Name Quik Stop Market #148 <br />Address 205 W. Lockeford Street, Lodi, CA 95240 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />A2. OWNER <br />Name Quik Stop Markets, Inc. <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />A3. C U P A <br />Name San Joaquin County Environmental Health <br />Address 1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Notified July 24, 2012 <br />Inspector Jeff Wong <br />Phone # 209-468-8257 <br />A4. TESTING CONTRACTOR <br />Name Walton Engineering, Inc. <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Lic # 617238 A, B, Haz <br />Contact Dulcinea Coven <br />Phone # 916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />Measuring Equipment Used: Caldwell System 2001 / Walton Engineering (Level Change Indicator) <br />1 <br />Tank Number <br />2 <br />3 <br />Product contained <br />Gasoline - 87 <br />Gasoline - 89 <br />Gasoline - 91 <br />Spill container capacity (US gallons) <br />5 <br />5 <br />5 <br />Spill container manufacturer <br />OPW <br />OPW <br />OPW <br />Spill container depth (inches) <br />14.00 <br />13.00 <br />14.00 <br />Is the spill container located in a sump? <br />Yes <br />Yes <br />Yes <br />Does sump have a liquid sensor installed? <br />No <br />No <br />No <br />Condition of spill container prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of spill container tested <br />Entire <br />Entire <br />Entire <br />Depth of water level from bottom (inches) <br />12.50 <br />11.50 <br />12.50 <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />0:10 <br />0:10 <br />Test start time <br />10:06 <br />10:43 <br />11:07 <br />Test end time <br />10:36 <br />11:13 <br />0:30 <br />11:37 <br />_ <br />Test duration (hr:min) <br />0:30 <br />0:30 <br />_ <br />Change in water level (t 0.000 inches) <br />0.001 <br />0.002 <br />0.000 <br />Pass/Fail threshold (0.005 inches / % Hr.) <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />L. COMMENTS: <br />Replaced the fill caps on the 89 and 91 products. <br />Replaced the swivell adaptor on the 91 product. <br />_ <br />Signature: <br />Technician: Curtis Carpenter 1837268 8020679 <br />WALTON <br />ENGINEERING, INC. <br />Date: August 3, 2012 <br />w zuiz waton rngmeenng, mc. <br />