My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 8:15:16 AM
Creation date
6/23/2020 6:54:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232257_205 W LOCKEFORD_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main 8blet, Stockton, CaMbmia 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.stgov.org/eWAl1tiiii.html <br />CONTINUATION FORM <br />Page: 3 of 3 <br />OFFICIAL INSPECTION REPORT <br />Date: 08/05/11 <br />Facility Address: Quik Stop Market #148 205 W. Lockeford St. Lodi, CA 95240 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLAN 1 CLASS II or MINOR -Notice to Com <br />On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br />#2 Repairs to the failed 89 line secondary containment tested to pass on 9-21-09 and the six month <br />retesting was due by 3-21-10. Testing has not been completed and is 17 months past due. Secondary <br />containment systems installed on or after January 1, 2001 shall be tested upon installation, 6 months <br />after installation, and every 36 months thereafter. Correct immediately by scheduling a licensed, <br />certified, and trained contractor to complete the secondary containment six month retest of the repaired <br />89 line. This office must be provided with a testing notification at least 48 hours in advance. <br />13. The 87 product Bravo box float and chain in the Dispenser #1/2 sump failed to stop the flow of <br />product at the dispenser when tested. All monitoring equipment shall be maintained to activate an <br />audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The service <br />technician adjusted the chain and verified functionality. Corrected on site. <br />18. The 87 spill container in the fill sump without a sump sensor failed when tested. All spill containers <br />shall have a minimum capacity of five gallons and be capable of containing a spill or overfill until it is <br />detected or cleaned up. The spill container was replaced and retested during the inspection. Obtain a <br />permit from the EHD for this work within one business day. If a permit is not obtained within one <br />business day, a "Failure to Obtain a Permit" penalty will apply. <br />21. Liquid was observed in the 89 & 91 turbine sumps. If water could enter into the secondary <br />containment by precipitation or infiltration, it must be removed and disposed of properly. Technician <br />removed the liquid and placed it into the hazardous waste drum on site. Ensure that the sumps are <br />maintained free of liquid. Corrected on site. <br />Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br />each violation was corrected, including supporting documentation, by 9-5-11. <br />ALL END STAFF TIME ASSOCIATED WITN FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL w BILLED AT THE Glmm HOURLY RATE (;122 . <br />THMFACILJTY 13 kIPJECT TO REINSPECTION AT ANY TIME AT EHWS CURRENT HOURLY RATE. <br />EHD Inspect <br />Received Br <br />/ <br />Titl! <br />END 2302009 Rev OeMd10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.