My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1465
>
2300 - Underground Storage Tank Program
>
PR0232272
>
COMPLIANCE INFO_2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2022 1:42:01 PM
Creation date
6/23/2020 6:54:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0232272
PE
2361
FACILITY_ID
FA0003925
FACILITY_NAME
COS MUNICIPAL SERVICE CTR
STREET_NUMBER
1465
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206-1941
APN
16504015
CURRENT_STATUS
01
SITE_LOCATION
1465 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232272_1465 S LINCOLN_2000-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br />Software Version Installed: <br />Complete the followinz checklist: <br />❑ Yes U—No* <br />Is the audible alarm operational? <br />Ca"YSs-❑ No* <br />Is the visual alarm operational? <br />Yes _ ❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />es ❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />❑ Yes ❑ No*._ <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />/A <br />operational? <br />❑ Yes ❑ No*—j <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />/A <br />system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />Imonitoring <br />positive shut -down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑ Yes; ❑ No. <br />❑ Yes ❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />/A <br />mechanical overfill prevention. valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />❑ Yes* M No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />y <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* o <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; ❑ Water. If yes, describe causes. in Section E, below. <br />cy-Yes ❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />Yes 0 No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />v a <br />171 `3+j C. a <br />Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.