Laserfiche WebLink
Monitoring System Certification <br />D. Results of Testing/Servicing <br />Software Version Installed: 331.00 <br />Complete the following checklist: <br />0 Yes <br />0 No* <br />Is the audible alarm operational? <br />Yes <br />0 No* <br />Is the visual alarm operational? <br />Yes <br />[I No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />• Yes <br />0 No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />• Yes <br />F1 No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br />g N/A <br />operational? <br />• Yes <br />0 No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />g N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) El Sump/Trench Sensors; [I Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? 0 Yes; 0 No. <br />• Yes <br />0 No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br />g N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />• Yes* <br />0 No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E, below. <br />• Yes* <br />0 No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />0 Product; 0 Water. If yes, describe causes in Section E, below. <br />• Yes <br />0 No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />I <br />LO Yes <br />[I No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />FMI`111- Mwilt.-W773745T#71i # =#- #UT#rFTriW*7r'#Mi 7##1iT#7j-W# <br />Page 2 of 3 <br />