Laserfiche WebLink
11 <br />033MEMYL <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility CITY OF STOCKTON -- CORP YARD <br />Site 1465 S. LINCOLN ST. <br />Facility Contact <br />Person TERRY WILLIAMS <br />Make/Model of Monitoring System: AUTO STIK JR <br />Bldg. No.: <br />City: STOCKTON, CA <br />Zip: 95206 <br />Contact Phone No.: ( ) <br />Date of Testing/Servicing: 3110/2011 <br />B. Inventory of Equipment Tested/Certified <br />Chack the annronriata hoses to indicate snecific eauioment insoected/serviced: <br />Tank ID: 87 <br />Tank Size: 10 K <br />Tank ID: <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: MALT <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: LS -30A <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: LS -3 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: SUCTION <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DIE <br />Tank Size: 10 K <br />Tank ID: <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: MALT <br />❑ In -Tank Gauging Probe. <br />Model <br />® Annular Space or Vault Sensor. <br />Model: LS -30A <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: LS -3 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: SUCTION <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1/2 <br />Dispenser ID: 3/4 <br />® Dispenser Containment Sensor(s). <br />Model: BEI -406 <br />® Dispenser Containment Sensor(s). <br />Model: BEI -406 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8 <br />® Dispenser Containment Sensor(s). <br />Model: BEI -406 <br />® Dispenser Containment Sensor(s). <br />Model: BEI -406 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />-If the facility contains more tanKs or aispensers, copy mis Torm. mcwae information Tor every tanK ana aispenser ac me Tacmry. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is infortnation (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): ZANE NIMMO Signature: y— <br />Certification No.: A28446 License No: 04-1676 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2" STREET GALT, CA 95632 Date of Testing/Servicing: 3/10/11 <br />Monitoring System Certification <br />Page Iof4 ATTACHMENT - 132 <br />2/21/07 <br />