My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1465
>
2300 - Underground Storage Tank Program
>
PR0232272
>
COMPLIANCE INFO_2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 2:55:45 PM
Creation date
6/23/2020 6:54:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0232272
PE
2361
FACILITY_ID
FA0003925
FACILITY_NAME
COS MUNICIPAL SERVICE CTR
STREET_NUMBER
1465
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206-1941
APN
16504015
CURRENT_STATUS
01
SITE_LOCATION
1465 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232272_1465 S LINCOLN_2006-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
511
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />Appendflx N11 ^vlis <br />(Copies of Monitoring Sy,tem Certification form and UST Monitoring Plot Plan available athtt ://w )� <br />MONITORING SYSTEl CERTIFICATIONr� <br />For Use By All Jurisdictions Within the State of California 0 ') �d09 <br />Authority Cited. Chapter 6.7, health and Safety Code; Chopler 16, Division 3, Title 23, California Co 6ulations <br />This form must be used to document testis and servicing of iiionitoring equipment. A separate certification or re o U �� �f��� <br />g g l i P P '� i <br />monitoring system control by the technician who performs the work. A copy of this form must be provided to the tank ys INEF, <br />The <br />owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: City of Stockton <br />Site Address: 1465 S. Lincoln St. <br />Facility Contact Person: Terri Williams <br />Make/Model of Monitoring System: I- uto-Stile Jr. <br />B. Inventory of Equipment Tcst-cd/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/scrNices <br />Tank ID: #1 Unleaded <br />El In -Tank Gauging Probe. M(,,dc1: 7100 EBW <br />(x)Annular Space or Vault Sensor. M% -:)del: LS -30A <br />(x)Piping Sump / Trench; Sensor(s). Model: LS -3A <br />❑ Fill Sump Sensor(s). Model: <br />( )Mechanical Line Leak Detector. Model: <br />❑ Electronic Line beak Detector. Model: _ <br />❑ Tank Overfill / l ligh-Level Sensor. Model• <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: #2 Diesel <br />(x)In-Tank Gauging Probe. M -del: 7100 EBW <br />❑x Annular Space or Vault Sensor. Model: LS -30A <br />❑x Piping Sump /Trench Sensor(s). Model: LS -3A <br />❑ Fill Sump Sensor(s). Model: <br />C3 Mechanical Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / Iligh-Level Sensor. Model: _ <br />❑ Other (spec iry equipment type and mode; in Section E on Page 2) <br />Dispenser 1D: 1 and 2 <br />(x)Dispenser Containment Sensor(s). Modcl: 406 Beaudreau <br />Shear Valve(s). <br />( )Dispenser Containment Float(s) and Chain(s). _ <br />Dispenser Ill. 3 and 4 <br />❑x Dispenser Containment Sensor(s). Mod, I: 406 Beaudreau <br />Shear Valve(s). <br />❑ Disnenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5 and 6 <br />x❑ Dispenser Containment Sensor(s). Model: 406 Beaudreau <br />Shear Valve(s). <br />❑Dispenser Containment Float(s) and Cb,in(s). <br />*If the facility contains more tanks or dispensers, copy this form <br />Bldg. No.: Corporation Yard <br />City: Stockton Zip 95206 <br />Contact Phor.., No.: 209-937-7416 <br />Date of Testing/Servicing: March 19, 2009 <br />Tsink ID: <br />DI rn- I'ank Gauging Probe. <br />Model: <br />U Annular Space or Vault Sensor. <br />Model: <br />C. Pining Sump/ Trench Sensor(s). <br />Model: <br />U 1 1 1 Sump Sensor(s). <br />Model: <br />❑ Mt:hanical Line Leak Detector. <br />Model: <br />C] FI,_ :6onic Line Leak Detector. <br />Model: <br />U Tar'!; Overfill /I ligh-Level Sensor. <br />Model: _ <br />L7 C' her (specify equipment type and model in Section E on Page 2). <br />'fanh ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />C1 ;Vinular Space or Vault Sensor. <br />Model: <br />tiling Sump / Trench Sensor(s). <br />Model: <br />O fill Sump Sensor(s). <br />Model: <br />'%1cr.:hanieal Line Leak Detector. <br />Model: <br />L.1 I:icctronic Line beak Detector. <br />Model: _ <br />1 "1' ::1< Overfill / ITigh-Level Sensor. <br />Model: <br />t` -;ci (specify equipment type and model in Section E on Page 2). <br />I3isih ;rser ID: 7 and 8 <br />(I D1, )enser Containment Sensor(s). <br />`A .'111,1i-valve(s). <br />�_d :)i,nt:nser Containment Float(s) and <br />h 1< ser ID: <br />' _'._.,eraser Containment Sensor(s). <br />Valve(s). <br />I' s,miser Containment Float(s) and <br />r .�; cnser Containment Sensor(s). Model: <br />a Vatvc(s). <br />unser Containment Float(s) and Chain(s). <br />Model: 406 Beaudreau <br />Model: <br />Include n , Pr C:on for ever), tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified in this docanreni was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. msr ,;,:r:= <br />
The URL can be used to link to this page
Your browser does not support the video tag.