My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
147
>
2300 - Underground Storage Tank Program
>
PR0232353
>
COMPLIANCE INFO_1988-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 9:38:51 AM
Creation date
6/23/2020 6:54:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2007
RECORD_ID
PR0232353
PE
2361
FACILITY_ID
FA0003789
FACILITY_NAME
TWO GUYS FOOD & FUEL
STREET_NUMBER
147
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19608071
CURRENT_STATUS
01
SITE_LOCATION
147 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232353_147 E LATHROP_1988-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
409
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Champion Precision Testing. <br />PO Box 13059 Sacramento, Ca 95813-3059 <br />(916) 927-1557 Fax (916) 927-7345 <br />Mechanical Leak Detector Test Data Sheet <br />Site Name o FZA 9 , —a(jJ o�—Fzle t Date t I - ( — C y <br />Address 4-A 1� L ✓r3 �✓ > t4 <br />Test information <br />Comments: <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct, The mechanical leak detector test pass/fail is determined using a low flow <br />threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Chamgion Precision Testing <br />Technician nn 4c Veeder-Root # f Z <br />Signature <br />Revision 5.,,0 1 <br />1 <br />2 <br />3 <br />4 <br />5 <br />Product <br />Manufacturer <br />Pe-Tiv <br />Fe <br />- P= -Tri <br />Model <br />S7'f� ele-n <br />5 —1/0 <br />Resiliency <br />Ire) <br />I <br />Opening Time <br />� <br />Test Leak Rate (ml/min) <br />(gph) <br />Metering PSI <br />2,q <br />76 <br />'30 <br />PASS or FAIL <br />Comments: <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct, The mechanical leak detector test pass/fail is determined using a low flow <br />threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Chamgion Precision Testing <br />Technician nn 4c Veeder-Root # f Z <br />Signature <br />Revision 5.,,0 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.