Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 1 PRESSURE ❑ 2. SUCTION ❑ 3 GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ❑ i. SINGLE WALL 1k3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER ❑ 2 DOUBLE WALL 1195. UNKNOWN ❑ 2. DOUBLE WALL ❑99. OTHER <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL ❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑95 UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ 6. FLEXIBLE(HDPE) ❑99. OTHER <br /> At 4. FIBERGLASS ❑ S. FLEXIBLE(HDPE) ❑99. OTHER. ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ 5 STEEL WI COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL W/COATING 1195. UNKNOWN <br /> VII.PIPING LEAK DETECTION(Check alf that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check ad that apply): <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION;*AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 0.2 GPH TEST <br /> ❑ 2. MONTHLY 0.2 GPM TEST ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ' ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 0.4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): . <br /> ❑ S. DAILY VISUAL kfONITORINC OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPM) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check as that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPM) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9 BIENNIAL INTEGRITY TEST(0.1 GPM) - <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check a8 that apply): PRESSURIZED PIPING(Check as that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) W.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> ❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ <br /> DISCONNECTION b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> ❑ C. NO AUTO PUMP SHUT OFF ❑ C. NO AUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION ' <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPM) - <br /> SUCTIOWGRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: .. <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check ak that apply) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUALaALARMS ALARMS " <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 1&ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 17. DAILY VISUAL CHECK I❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ S. TRENCH LINER t MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑6. NONE <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify th t the infofmalan provided heroin is true and accurate to the best of my knowledge. <br /> SIG RE OF OWN DATE <br /> Of CIANEWOPERAjKlOnno TITLE OF ER/OPERATOR <br /> Permit Number(For local use only) Permit Approved(For local use only) Permit Expiration Daft(Forlocal use only) <br /> CUPAFORM(4/99) <br /> Formerly SWRCB Form B <br />