Laserfiche WebLink
STATE OF CALIFORNa WATER RESOURCES CONTR OARD <br /> FORM `B': UNDERGROUND STORAGE TANK PRRAMo <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> if <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED a r <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 44 <br /> &A-iO <br /> FARM TANK-YES❑ NO (�$ <br /> !"I <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: el-er-- <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: /0,060 <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED, OMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. EX1 UNLEADED ❑ 2 LEADED ❑3 DIESEL <br /> F-] 3 CHEMICAL PRODUCT ❑ 4 OIL 1�1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> El5 HAZARDOUS ❑ 80 EMPTY [:]95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF 1:91 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE F-17 ALUMINUM F-18 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ <br /> C. INTERIOR 1 RUBBER LINED ALKYD LINING F-] 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING 6 UNLINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑ 3 VINYL WRAP Dn 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A 02 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE 04 A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A 614 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECOND RY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 2�A P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS JPA 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN <br /> GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> FPERMITNUMBER <br /> ffff] <br /> JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 12- 35 P�l <br /> AGENCY�ILITY ID# APPROVED SY NAME / PHONE#WITH AREA CODE <br /> 0 <br /> PERMIT APPROVAL DATE PERMIT EX (RATION DATE <br /> PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIE A FACILITY/SITE APPLICATION, FORM`A',UNLESS A RENT FORMA' HAS BEEN FILED /�Y• <br /> DATA PROCESSING COPY <br />