Laserfiche WebLink
�s r; �.�,�,� x '" .> a�n y�y., +9, s � 3+�•..,� ,� ,� >g 4 t kx ..,s,. sc t�'�"i -a }�¢•iA "�'. �,'� �i'r�� >: �; <br /> 5 <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT " ��r" `�"��� ���� <br /> 1868 E.Hazelton Ave. • Stockton, CA 95205-6232 • Phone 209 468-3420 h <br /> Donna Heran,R.E.H.S.,Director , <br /> < r <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit — Permit <br /> Record ID Number Program Code and Description Valid <br /> PRO518130 PT0011861 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2013 To 12/31/2013 <br /> Hazardous Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20, Chap.6.5,Art.2-13, <br /> Sec.25100 et seq and Title 22, rnia Code of Regulations,Chap.20____ ________________ <br /> PR0232353 2300-U DERGROUND STORAGE TANK FACILITY 1/1/2013 To 12/31/2013 <br /> Under round Stora a ank Pro r <br /> California Health and Safe y ode, Div.20,Chap.6.7 and Title 23,California Code of Regulations,Chap_16. <br /> -- -- <br /> P/E Tank# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 2362 1 . 390002323530235301 PT0004872 10,000 REGULAR UNLEADED Active, billable DOUBLE-WALL Continuous Interstitial Monitoring <br /> 2360 2 390002323530235302 PT0004873 10,000 PREMIUM UNLEADED Active, billable DOUBLE-WALL Continuous Interstitial Monitoring <br /> 2360 3 390002323530235303 PT0007488 10,000 DIESEL Active, billable DOUBLE-WALL Continuous Interstitial Monitoring <br /> BOE ID#: 44024690 tY <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditionsa t <br /> established by San Joaquin County. .' <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the permit. <br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5;and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was <br /> performed. <br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 1 1) Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> 13) A"Conditional"Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- <br /> PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s) Valid only for: CARDOZA ED & DOLORES <br /> DBA: TWO GUYS FOOD & FUEL " <br /> Tank Owner. CARDOZA ENTERPRISES <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> TWO GUYS FOOD & FUEL Facility ID FA0003789 <br /> Regulated Facility: <br /> 147 E LATHROP RD Account ID AR0003374 <br /> LATHROP CA 95330 Issued 2/19/2013 <br /> Billing Address: <br /> TWO GUYS FOOD & FUEL <br /> 147 E LATHROP RD <br /> LATHROP CA 95330 <br /> 7023.rp1 <br />