Laserfiche WebLink
SYNEM SET-UP REP0RTOPage3) <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />JAN 1. 1996 <br />START TIME : 7:52 AM <br />TEST RATE :0.20 GAL.FHR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP- - <br />L 1:91 STP SUMP <br />TRI-STATE (SINGLE FLQAT) <br />CATEGORY : STP SUMP <br />L 2:89 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY . STP SUMP <br />L 3:87 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 4:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 5:89 ANIlULAR <br />TRI-STATE (SINGLE FLOAT> <br />CATEGORY : ANNULAR SPACE <br />L 6:91 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />SMARTSENSOR SETUP <br />s 1:DISP 1-2 FLOW <br />CATEGORY AIR FLOW METER <br />9 2:DISP 3-4 FLOW <br />CATEGORY AIR FLOW METER <br />s 3:PRESSURE <br />CATEGORY VAPOR PRESSURE <br />02006 Walton Engineering, Inc. <br />OUTPUT RELAY SETUP <br />R 1:89 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 0: 2 <br />1N -TANK ALARMS <br />T 2:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:87 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 0: 1 <br />IN -TANK ALARMS <br />T 1:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 3:FUEL ALARM <br />L 3:SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />ISD SITE ALARMS <br />ISA GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 3:91 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 0: 3 <br />IN -TANK ALARMS <br />T 3:LOW PRODIK'T ALARM <br />LIQUID SENSOR ALMS <br />L 1:FUEL ALARM <br />L I:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISP HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />EVR:ISD SETUP <br />EVR TYPE: VACUUM ASSIST <br />VACUUM ASSIST TYPE <br />HEALY VAC <br />NOZZLE A�'L RANGE <br />MW 1.15 MIN: 0.95 <br />VAPOR PROCESSOR TYPE <br />NO VAPOR PROCESSOR <br />ANALYSIS TIMES <br />TIME: 11:59 PM <br />DELAY MINUTES: 1 <br />ACCEPT HIGH ORVR: <br />DISABLED <br />ISD <br />HOSE TABLE <br />1 2 3 <br />4 <br />ID <br />FP <br />FL <br />HL <br />AA <br />RR <br />------------------------ <br />01 <br />01 <br />01 <br />02 <br />01 <br />UU <br />02 <br />02 <br />02 <br />02 <br />01 <br />UU <br />03 <br />03 <br />03 <br />02 <br />02 <br />UU <br />04 <br />04 <br />04 <br />02 <br />02 <br />UU <br />ISD AIRFLOW METER MAP <br />ID SERIAL NUM LABEL <br />------------------------ <br />1 14656 DISP 1-2 F <br />2 14660 LISP 3-4 F <br />ISD FUEL GRADE <br />HOSE MAP <br />1 2 3 <br />4 <br />FP MHH MHH MHH <br />MHH AA <br />------------------------ <br />01 001 101 201 <br />U U 1 <br />02 002 102 202 <br />U U 1 <br />03 003 103 203 <br />U U 2 <br />04 004 104 204 <br />U U 2 <br />LABEL TABLE <br />------------------------ <br />1: UNASSIGNED <br />2: BLENDS <br />3: REGULAR <br />4: MID GRADE <br />5: PREMIUM <br />6: GOLD <br />7: BRONZE <br />8: SILVER <br />q.: BLEND2 <br />10:.BLEND4 <br />SOFTWARE REVISION LEVEL <br />VERSION 327.04 <br />SOFTWARE# 346327-100-E <br />CREATED - 07.02.06.10.28 <br />S-MODULEO 330160-004-a <br />SYSTEM FEATURES: <br />PERIODIC IN -TANK TESTS <br />ANNUAL IN -TANK TESTS <br />ISD <br />PMC <br />