My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2005-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 4:16:46 PM
Creation date
6/23/2020 6:55:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2009
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2005-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: o Pressure o Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />uescriptlon <br />Tank #1 <br />Tank #2 <br />Tank #3 <br />Tank product <br />Gasoline - 87 <br />Gasoline - 89 <br />Gasoline - 91 _ <br />Sump material <br />FRP <br />FRP <br />FRP <br />Sump diameter (inches) <br />42 <br />42 <br />42 <br />Sump depth (inches) <br />49 <br />49 <br />45 <br />Height from tank top to highest <br />7 <br />7 <br />7 <br />piping penetration (inches) <br />0:15 <br />0:15 <br />0:15 <br />Height from tank top to lowest <br />9 <br />9 <br />9 <br />electrical penetration (inches) <br />0.0020 <br />0.0020 <br />0.0020 <br />Method of sump attachment to tank <br />Manway <br />Manway <br />Manway <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Unknown <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Depth of water level from tank top (inches) <br />16 <br />18 <br />19 <br />Wait time for water level to stabilize (hr:min) <br />0:15 <br />0:10 <br />0:10 <br />Test start time <br />10:53 AM <br />12:44 PM <br />9:39 AM <br />Initial Probe Reading <br />2.2058 <br />4.5716 <br />7.1856 <br />Test end time <br />11:08 AM <br />12:59 PM <br />9:54 AM <br />Final Probe Reading <br />2.2041 <br />4.5707 <br />7.1856 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />-0.0017 <br />-0.0009 <br />0.0000 <br />Pass/Fail threshold (±0:0020 inches /; Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />V 2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.