Laserfiche WebLink
SY EM SET-UP REPOR (Page 1) <br /> SYSTEM SETUP - - _ _ - COMM ATIONS SETUP - - IN-TANK SETUP <br /> JUL l3. 2012 8:13 A M - - - - - - - - - - - - <br /> PORT SETTINGS: T 1 :Unleaded-Regulerr <br /> PRODUCT CODE A <br /> SYSTEM UNITS COMM BOARD 1 (RS-232) THERMAL COEFF : .000700 <br /> U.S. BAUD RATE 1200 TANK DIAMETER 96.00 <br /> SYSTEM LANGUAGE PARITY ODD TANK PROFILE 4 PTS <br /> ENGLISH STOP BIT 1 STOP FULL VOL : 9816 <br /> SYSTEM DATE/TIME FORMAT DATA LENGTH: 7 DATA 72.0 INCH VOL 8414 <br /> KION DD YYYY HH:MM:SS xM RS-232 SECURITY 45.0 INCH VOL 5291 <br /> CODE : DISABLED 24.0 INCH VOL : 2027 <br /> QUIK STOP 152 <br /> 1721 S CHEROKEE COMM BOARD 2 (RS-232) FLOAT SIZE: 4.0 IN. <br /> LOD1 CA 95240 BAUD RATE : 9600 <br /> 209-369-7375 PARITY NONE <br /> STOP BIT 2 STOP WATER WARNING 1 .0 <br /> SHIFT TIME 1 6:00 AM DATA LENGTH: 8 DATA HIGH WATER LIMIT: 2.0 <br /> SHIFT TIME 2 DISABLED RS-232 SECURITY ; OR LABEL VOL: 9131ti <br /> SHIFT TIME 3 DISABLED CODE : DISABLED OVERFILL LIMIT 816 <br /> SHIFT TIME 4 DISABLED <br /> COMM BOARD : 3 (EDIM ) 8834 <br /> TANK PER TST NEEDED WRN RS-232 SECURITY HIGH PRODUCT 95%: <br /> DISABLED CODE : DISABLED 9325 <br /> TANK ANN TST NEEDED WRN DELIVERY LIMIT 1004 <br /> DISABLED COMM BOARD 5 iS-SAT ) 981 <br /> : <br /> LINE RE-ENABLE METHOD BAUD RATE 9600PARITY NONE LOW PRODUCT 600 <br /> PASS LINE TEST STOP BIT 1 STOP LEAK ALARM LIMIT: 99 <br /> DATA LENGTH: 8 DATA SUDDEN LOSS LIMIT: 99 <br /> LINE PER TST NEEDED WRN RS-232 SECURITY TANK TILT 0.00 <br /> DISABLED CODE : DISABLED PROBE OFFSET 0.00 <br /> LINE ANN TST NEEDED WRN DTR NORMAL STATE: HIGH <br /> DISABLED SIPHON MANIFOLDED TANKS <br /> PRINT TC VOLUMES AUTO TRANSMIT SETTINGS: Tit: NONE <br /> ENABLED LINE MANIFOLDED TANKS <br /> AUTO LEAK ALARM LIMIT Tit: NONE <br /> TEMP COMPENSATION DISABLED <br /> VALUE (DEG F ) : 60.0 AUTO HIGH WATER LIMIT LEAK MIN PERIODIC: 0% <br /> STICK HEIGHT OFFSET DISABLED 0 <br /> DISABLED AUTO OVERFILL LIMIT <br /> ULLAGE: 90% DISABLED <br /> AUTO LOW PRODUCT LEAK. MIN ANNUAL : 04 <br /> H-PROTOCOL DATA FORMAT DISABLED 0 <br /> HEIGHT AUTO THEFT LIMIT <br /> DAYLIGHT SAVING TIME DISABLED PERIODIC; TEST TYPE <br /> ENABLED AUTO DELIVERY START STANDARD <br /> START DATE DISABLED <br /> MAR WEEK 2 SUN AUTO DELIVERY END ANNUAL TEST FAIL <br /> START TIME DISABLED ALARM DISABLED <br /> AM AUTO EXTERNAL INPUT ON <br /> END DATE DISABLED PERIODIC TEST FAIL <br /> NOV WEEK 1 SUN AUTO EXTERNAL INPUT OFF <br /> END TIME DISABLED ALARM DISABLED <br /> 2:00 AM AUTO SENSOR FUEL ALARM GROSS TEST FAIL <br /> DISABLED <br /> RE-DIRECT LOCAL PRINTOUT AUTO SENSOR WATER ALARMALARM DISABLED <br /> DISABLED DISABLED HMV TEST AVERAGING: OFF <br /> AUTO SENSOR OUT ALARM <br /> EURO PROTOCOL PREFIX DISABLED PER TEST AVERAGING: OFF <br /> S TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREHK:OFF <br /> DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD : 10.000 <br /> ®2012 Walton Engineering,Inc. <br />