SY EM SET-UP REPOR (Page 3) <br /> OUTPUT RELAY SETUP SMARTSENSOR SETUP SOFTWARE REVISION LEVEL <br /> - - - - - - - - - - - - - - - - - - - - - - - - VERSION 330.01 <br /> SOFTWARE# 346330-100-13 <br /> R 1 :89 3 1 :1-2 CREATED - 10.07.23.17.25 <br /> TYPE: CATEGORY AIR FLOW METER <br /> STANDARD S MODULEit 330160-004-a <br /> NORMALLY CLOSED a 2:3-4 SYSTEM FEATURES: <br /> CATEGORY AIR FLOW METER PERIODIC IN-TANK. TESTS <br /> TANK 4: 2 ANNUAL IN-TANK TESTS <br /> 3 3:VAPOR PRESSURE ISD <br /> IN-TANK ALARMS <br /> CATEGORY VAPOR PRESSURE <br /> — — — - <br /> T 2:LOW PRODUCT ALARM EVR:,ISD SETUP <br /> LIQUID SENSOR ALMS <br /> L 2:FUEL ALARM <br /> L 2:SENSOR OUT ALARM EVR PE: VACUUM ASSIST <br /> L 2:SHORT ALARM VACUUM AeSIST TYPE <br /> ISD SITE ALARMS HEALY VAC <br /> ISD GROSS PRES FAIL NOZZLE A!L RANGE <br /> ISD DEGRCI PRES FAL <br /> ISD VAPOR LEAK FAIL MAX: 1 .15 MIN: 0.95 <br /> ISD VP FRES FAIL VAPOR PROCESSOR T.'PE <br /> ISD HOSE ALARMS NONE <br /> ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL ANALYSIS TINES <br /> ALL:FLOW COLLECT FAIL TIME: 11 :59 PM <br /> R 2:87 DELAY MINUTES: 1 <br /> TYPE: <br /> STANDARD ACCEPT HIGH ORVk: <br /> NORMALLY CLOSED DISABLED <br /> TANK A: 1 ISD HOSE TABLE <br /> ID FP FL HL AA RR <br /> IN-TANK ALARMS --------------------- -- <br /> T 1 :LOW PRODUCT ALARM 01 01 01 02 01 03 <br /> 02 02 02 02 01 03 <br /> LIQUID SENSOR ALMS 03 03 03 02 02 03 <br /> L 3:FUEL ALARM 04 04 04 02 02 03 <br /> L 3:SENSOR OUT ALARM <br /> L 3:SHORT ALARM ISD AIRFLOW METER MAP , <br /> ISD SITE ALARMS ID SERIAL NUM-LABEL <br /> -- -- <br /> ISD GROSS FRES FAIL 1 39364 - 1-2 <br /> ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL 2 14660 3-4 <br /> ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL ISD FUEL GRADE HOSE MAF` <br /> ALL:FLOW COLLECT FAIL 1 2 3 4 <br /> FP MHH MHH 111HH rIHH H; <br /> R3:91 ------------------------- <br /> TYPE: 01 001 101 201 U U 1 <br /> STANDARD 02 002 102 202 U U 1 <br /> NORMALLY CLOSED 03 003 103 203 U U 2 <br /> 04 004 104 204 U U 2 <br /> TANK 0: 3 <br /> LABEL TABLE <br /> 1N-TANK ALARMS --------------=----- <br /> T 3:LOW PRODUCT ALARM 1 : UNASSIGNED <br /> 2: BLEND3 <br /> . LIQUID SENSOR ALMS 3: REGULAR <br /> L 1 :FUEL ALARM 4: MID GRADE <br /> L 1 :SENSOR OUT ALARM 5: PREMIUM <br /> L 1 :SHORT ALARM 6: GOLD <br /> 7: BRONZE <br /> ISD SITE ALARMS 8: SILVER <br /> ISD GROSS PRES FAIL 9: BLEND2 <br /> ISD DEGRD PRES FAIL 10: BLEND4 <br /> ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL <br /> ALL:FLOW COLLECT FAIL <br /> 02012 Walton Engineering,Inc. <br />