My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 4:20:47 PM
Creation date
6/23/2020 6:55:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2010-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITV#ING SYSTEM CERTHWATION <br />MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC <br />CERTIFICATION /TEST DATE: July 15, 2011 <br />A1. FACILITY <br />A2. OWNER <br />Name Quik Stop Market #152 <br />Name Quik Stop Markets, Inc. <br />Address 1721 S. Cherokee Lane #1, Lodi, CA 95240 <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />Contact Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 600 E. Main Street, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified July 6, 2011 <br />Lic # 617238 A, B, Haz <br />Inspector Aris Cacapit <br />Contact Dulcinea Covan <br />Phone # 209-468-8257 <br />Phone # 916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />131: <br />TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline - 89 <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />■ Annular Space or Vault Sensor Model: 0794390-409 <br />■ Annular Space or Vault Sensor Model: 0794390-409 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br />■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />Tank #3 (Product): Gasoline - 91 <br />Tank #4 (Product): _ <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />■ Annular Space or Vault Sensor Model: 0794390-409 <br />❑ Annular Space or Vault Sensor Model: <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />132: DISPENSERS/UDC's <br />Dispenser # : 1 -2 <br />Dispenser # : 3-4 <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />■ Shear Valves <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up <br />■ Alarm History Report <br />WALTON <br />Signature: ENGINEERING. INC;. <br />Technician / Cert #: Gerardo Guzman / B35394 5242481 -UT <br />Date: July 1 S , 201 1 <br />to zui i wanon tnglneenng, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.