Laserfiche WebLink
SY EM SET-UP REPORT Page 2) <br />T 3:Premium_Unlead UTPUT RELAY SETUP R 3:91 <br />PRODUCT '•ODE B - - - - - - - - - <br />THERMAL COEFF <br />:.000700 <br />TANK DIAMETER <br />96.00 <br />TANK. PROFILE <br />4 PTS <br />FULL VOL <br />7950 <br />72.0 INCH VOL <br />682E <br />48.0 INCH VOL <br />4299 <br />24.0 INCH VOL <br />1629 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING 1.0 <br />HIGH WATER LIMIT: 2.0 <br />MAX OR LABEL VOL: 7950 <br />OVERFILL LIMIT 90% <br />7155 <br />HIGH PRODUCT 95%6 <br />7552 <br />DELIVERY LIMIT : 10 <br />795 <br />LOW PRODUCT 600 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN! LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MANIFOLDED TANK <br />TO: NONE <br />R 1:89 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />IN -TANK ALARMS <br />T 2:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:87 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 1 <br />LEAK. MIN PERIODIC: 0% IN -TANK ALARMS <br />0 T 1:LOW PRODUCT ALARM <br />LEAK MIN ANNUAL 0% LIQUID SENSOR ALMS <br />0 L 3:FUEL ALARM <br />L 3:SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD 10.00% <br />02011 Walton Engineering, Inc. <br />LSD SITE ALARMS <br />ISD GROSS FRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 3 <br />IN -TANK ALARMS <br />T 3:LOW PRODUCT ALAR! -,1 <br />LIQUID SENSOR ALMS <br />L I:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />L 1:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />LIQUID SENSOR SETUP <br />L 1:91 STP SUMP <br />TRI-STATE (SINGLE FLOAT: <br />CATEGORY : NTP SUMP <br />L 2:89 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:67 STP SUMP <br />TRI-STATE (SINGLE FLOATt <br />CATEGORY : STP SUMP <br />L 4:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 5:89 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 6:91 ANNULAR <br />TRI-STATE (SINGLE FLOATS <br />CATEGORY : ANNULAR SPACE <br />