Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FOW <br />UNDERGROUND STORAGE TANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) <br />TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections I, 11, III, IV, and IX below) <br />430 <br />X 1. NEW PERMIT ❑ 3. RENEWAL PERMIT ❑ 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ S. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 431a DATE EXISTING UST DISCOVERED: <br />430b <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency, Use Onl), <br />_ <br />I <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) <br />3 <br />Quik Stop #152 <br />BUSINESS SITE ADDRESS 103 CITY <br />104 <br />1721 S. Cherokee Lane #I Lodi <br />1 <br />II. TANK DESCRIPTION <br />TANK ID # 432 <br />TANK MANUFACTURER 433 <br />TANK CONFIGURATION: THIS TANK IS <br />434 <br />1 <br />Xerxes <br />X 1. A STAND-ALONE TANK <br />❑ 2. ONE IN A COMPARTMENTED UNIT. <br />Complete one page for each compartment in the unit. <br />DATE UST SYSTEM INSTALLED 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS IN THE UNIT <br />437 <br />10,000 <br />1 <br />III. TANK USE AND CONTENTS <br />TANK USE x la. MOTOR VEHICLE FUELING ❑ 1b. MARINA FUELING ❑ lc. AVIATION FUELING <br />439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />439a <br />CONTENTS PETROLEUM: X la. REGULAR UNLEADED ❑ lc. MIDGRADE UNLEADED ❑ lb. PREMIUM UNLEADED <br />440 <br />❑ 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): <br />440a <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ 11. OTHER NON -PETROLEUM (Specify): <br />449b <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL x 2. DOUBLE WALL ❑ 95. UNKNOWN <br />443 <br />PRIMARY CONTAINMENT ❑ I. STEEL X 3. FIBERGLASS ❑ 6. INTERNAL BLADDER <br />444 <br />❑ 7. STEEL + INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />444a <br />SECONDARY CONTAINMENT ❑ 1. STEEL X 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED <br />445 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />445a <br />OVERFILL PREVENTION ❑ 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT x 3. FILL TUBE SHUT-OFF VALVE <br />452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT / WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION ❑ 1. SINGLE -WALLED x 2. DOUBLE -WALLED ❑ 99. OTHER <br />460 <br />SYSTEM TYPE x 1. PRESSURE ❑ 2. GRAVITY ❑ 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)] <br />458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL X 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC <br />464 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER(Specify): <br />464a <br />SECONDARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC <br />464b <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />464c <br />PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE <br />4644 <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464e <br />464el <br />VENT SECONDARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464f <br />464fl <br />VR PRIMARY CONTAINMENT ❑ i. STEEL X 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />4648 <br />464 1 <br />VR SECONDARY CONTAINMENT ❑ L STEEL X 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464h <br />464hl <br />VENT PIPING TRANSITION SUMP TYPE ❑ 1. SINGLE WALL x 2. DOUBLE WALL ❑ 90. NONE <br />4641. <br />RISER PRIMARY CONTAINMENT x L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464j <br />4641 <br />RISER SECONDARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464k <br />464k1 <br />FILL COMPONENTS INSTALLED x 1. SPILL BUCKET x 3. STRIKER PLATE/BOTTOM PROTECTOR x 4. CONTAINMENT SUMP <br />45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE X 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE <br />469a <br />CONSTRUCTION MATERIAL ❑ L STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHER (Specify) <br />469b -c <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ❑ 6. ISOLATION <br />448 <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full compliance with legal requirements. <br />APPLICANT SIGNA <br />DATE470. <br />APPLICANT NAME (print) Dulcinea Covan 471. <br />APPLICANT TITLE Compliance Manager <br />472. <br />UPCF UST -13 - 1/1 Rev. (12/2007) <br />