COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2021 9:58:11 AM
Creation date
6/23/2020 6:55:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K. SPILL CONTAINER TEST RESULTS <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inche <br />Wait time for water level to stabilize (hr: <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (t 0.000 inches) <br />Pass/Fail threshold (0.005 inches I % Hr. <br />TEST RESULT <br />L. COMMENTS: <br />Replaced the fill cap on the 91 product. <br />1 <br />Gasoline - 87 <br />5 <br />OPW <br />12.50 <br />Yes <br />No <br />Dry <br />Entire <br />12.00 <br />0:10 <br />9:46 <br />10:46 <br />1:00 <br />0.001 <br />0.005 <br />PASS <br />usea: LaKe i est <br />2 <br />Gasoline - 91 <br />5 <br />OPW <br />12.00 <br />Yes <br />No <br />Dry <br />Entire <br />11.50 <br />0:10 <br />10:11 <br />11:11 <br />1:00 <br />0.000 <br />0.005 <br />PASS <br />3 <br />Diesel <br />5 <br />OPW <br />12.50 <br />Yes <br />No <br />Dry <br />Entire <br />12.00 <br />0:10 <br />9:46 <br />10:46 <br />1:00 <br />0.002 <br />0.005 <br />PASS <br />WALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Curtis Carpenter/ B37258 8020679 Date: June 20, 2018 <br />ANNUAL SPILL CONTAINER TEST REPORT <br />TEST DATE: <br />June 20, 2018 <br />A1. FACILITY <br />A2. OWNER <br />Name <br />Quik Stop Market #152 <br />Name Quik Stop Markets, Inc. <br />Address <br />1721 S. Cherokee Lane #1, Lodi, CA 95240 <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />Phone # 510-657-8500 <br />Contact <br />Roger Batra <br />I Contact Debbie Markovich <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />June 05, 2018 <br />Lic # 617238 A, B, Haz <br />Inspector <br />None <br />Contact Veronica Freitas <br />Phone # <br />209-468-3442 <br />Phone # 916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inche <br />Wait time for water level to stabilize (hr: <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (t 0.000 inches) <br />Pass/Fail threshold (0.005 inches I % Hr. <br />TEST RESULT <br />L. COMMENTS: <br />Replaced the fill cap on the 91 product. <br />1 <br />Gasoline - 87 <br />5 <br />OPW <br />12.50 <br />Yes <br />No <br />Dry <br />Entire <br />12.00 <br />0:10 <br />9:46 <br />10:46 <br />1:00 <br />0.001 <br />0.005 <br />PASS <br />usea: LaKe i est <br />2 <br />Gasoline - 91 <br />5 <br />OPW <br />12.00 <br />Yes <br />No <br />Dry <br />Entire <br />11.50 <br />0:10 <br />10:11 <br />11:11 <br />1:00 <br />0.000 <br />0.005 <br />PASS <br />3 <br />Diesel <br />5 <br />OPW <br />12.50 <br />Yes <br />No <br />Dry <br />Entire <br />12.00 <br />0:10 <br />9:46 <br />10:46 <br />1:00 <br />0.002 <br />0.005 <br />PASS <br />WALTON <br />Signature: <br />ENGINEERING, INC. <br />Technician: Curtis Carpenter/ B37258 8020679 Date: June 20, 2018 <br />