PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br />Test Method By: 0 Manufacturer O Industry Standard O Professional Engr. O Other (see below) <br />Test Method Uses: O Pressure • vacuum o Hydrostatic o Other (see below) <br />Measuring Equipment Used: Vacuum Gauge (range 0 to 30 inches Hg) <br />Desr_rintinn Tank 01 Tank 42 Tank #3 <br />Product stored <br />Regular Gasoline <br />Premium Gasoline <br />Diesel <br />Tank manufacturer <br />Unknown <br />Unknown <br />Unknown <br />Tank material <br />FRP <br />FRP <br />FRP <br />Tank capacity (US gallons) <br />10,000 <br />10,000 <br />8,000 <br />Is this a multi -compartment tank? <br />No <br />No <br />No <br />Dry or Brine filled annular? <br />Dry <br />Dry <br />Dry <br />Monitoring system show normal annular? <br />Yes <br />Yes <br />Yes <br />Is water table above tank bottom? <br />Unknown <br />Unknown <br />Unknown <br />Was sensor removed for testing? <br />No <br />No <br />No <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Wait time for vacuum to stabilize (hr:min) <br />:15 <br />:15 <br />:15 <br />Test start time <br />10:30 AM <br />10:38 AM <br />10:53 AM <br />Initial vacuum (inches Hg) <br />7.0 <br />7.0 <br />7.0 <br />Test end time <br />11:30 AM <br />11:38 AM <br />11:53 AM <br />Final vacuum (inches Hg) <br />Test duration (hr:min) <br />7.0 <br />1:00 <br />7.0 <br />1:00 <br />7.0 <br />1:00 <br />Change in vacuum (inches Hg) <br />0.0 <br />0.0 <br />0.0 <br />Pass/Fail threshold (inches Hg / hour) <br />2.0 <br />2.0 <br />2.0 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />© 2017 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.