Laserfiche WebLink
• 0 <br /> " co' S A N X10 A Q U I N Environmental Health Department <br /> G <br /> ` COUNTY Linda Turkatte, REHS, Director <br /> cP i Kasey Foley,REHS,Assistant Director <br /> �c,Foa? Greatness grows here. <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RDI <br /> Rodney Estrada,REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu,REHS <br /> August 01, 2018 <br /> VERONICA FREITAS <br /> WALTON ENGINEERING <br /> PO BOX 1025 �1 s <br /> WEST SACRAMENTO, CA 95691 <br /> Re: QUIK STOP MARKET#2152 Amended-SR0079449 <br /> 1721 S CHEROKEE LN#1 <br /> LODI, CA 95240 <br /> The San Joaquin County Environmental Health Department(EHD)has completed the review of the application for a <br /> permit to replace the 87 STP sump sensor(with Veeder Root sensor#208)on the underground storage tank(UST) <br /> system at the above noted address. This work was completed on April 16, 2018 and sensor functionality was verified <br /> by the EHD during the routine imonitoring system certification on 6-20-2018; as such, no further testing is required <br /> for this sensor replacement at this time.The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Please be aware that inspections for emergency work must be scheduled within five days of permit <br /> approval. <br /> • Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of Regulations <br /> and the Health&Safety Code. If it is determined that a cold start is necessary, a copy of the <br /> alarm history shall be printed prior to performing the"cold start"of the monitoring system and <br /> made available at the time of EHD inspection. <br /> 4. If concrete will be broken near the tank, a secondary containment test must be performed on the <br /> tank once concrete is poured in accordance with the manufacturer's guidelines. <br /> 5. Any individual performing the work of a service technician must meet the following qualifications: <br /> a. Possess or be employed by a person who possesses one of several permissible valid, current <br /> contractor's licenses issued by the Contractors State License Board(may be issued to the <br /> installation company), or a Tank Tester's license issued to the individual by the State Water <br /> Board, and <br /> b. Possess or work under the direct and personal supervision of an individual physically present at <br /> the work site who possesses a valid, current California UST Service Technician certificate issued <br /> by the International Code Council(ICC), and <br /> c. Possesses a valid, current certificate of training from the manufacturer(s)of the component(s) <br /> being tested, repaired, or serviced. <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />