COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2021 9:58:11 AM
Creation date
6/23/2020 6:55:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description <br />Tank #1 <br />Tank #2 <br />Tank #3 <br />:15 <br />Tank product <br />Regular Gasoline <br />Premium Gasoline <br />Diesel <br />11:44 AM <br />Initial Probe Reading <br />Sump material <br />FRP <br />FRP <br />FRP <br />11:59 AM <br />12:19 PM <br />Sump diameter (inches) <br />42 <br />42 <br />42 <br />0.5511 <br />Test duration (hr:min) <br />Sump depth (inches) <br />49 <br />49 <br />45 <br />-0.0003 <br />-0.0004 <br />Height from tank top to highest <br />piping penetration (inches) <br />7 <br />7 <br />7 <br />Entire <br />Is system programmed for fail-safe operation? <br />Height from tank top to lowest <br />electrical penetration (inches) <br />9 <br />9 <br />9 <br />No <br />No <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Tank Collar <br />Yes <br />Was sensor properly replaced after testing? <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Dry <br />Port <br />Depth of water level from tank top (inches) <br />Comments: <br />12 <br />12 <br />12 <br />Wait time for water level to stabilize (hr:min) <br />:15 <br />:15 <br />:15 <br />Test start time <br />11:44 AM <br />12:04 PM <br />11:44 AM <br />Initial Probe Reading <br />5.6408 <br />4.3379 <br />0.5526 <br />Test end time <br />11:59 AM <br />12:19 PM <br />11:59 AM <br />Final Probe Reading <br />5.6405 <br />4.3375 <br />0.5511 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />-0.0004 <br />-0.0015 <br />ion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Unkonwn <br />Unkonwn <br />Unkonwn <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Depth of water level from tank top (inches) <br />Comments: <br />12 <br />12 <br />12 <br />Wait time for water level to stabilize (hr:min) <br />:15 <br />:15 <br />:15 <br />Test start time <br />11:44 AM <br />12:04 PM <br />11:44 AM <br />Initial Probe Reading <br />5.6408 <br />4.3379 <br />0.5526 <br />Test end time <br />11:59 AM <br />12:19 PM <br />11:59 AM <br />Final Probe Reading <br />5.6405 <br />4.3375 <br />0.5511 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0003 <br />-0.0004 <br />-0.0015 <br />Pass/Fail threshold (10.002 inches/ z Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />0 2017 Walton Engineering, Inc. <br />