My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2021 9:58:11 AM
Creation date
6/23/2020 6:55:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALTON, <br />ENGINEERING, INC. <br />Overiill Prevention Inspection - Or 61 and 71 Series Devices <br />Date: 10/1 /2018 <br />Owner: Quik Stop Market #152 <br />Facility: 1721 S. Cherokee In. <br />OPW Overfill Model Number: <br />Part 1 - Proner Height Setting Calculation <br />Part 2 - Device <br />Yes <br />Tank 1 <br />Tank 2 <br />Tank 3 <br />Tanlc 4 <br />Maximum Tank Volume Per: <br />A Gallons <br />9684 <br />9684 <br />7841 <br />Max shut off requirement for flapper is 95% <br />B 95% <br />.95 <br />.95 <br />.95 <br />Multiply Max tank volume by 95% <br />C Gallons <br />9200 <br />9200 <br />7449 <br />Yes <br />Use tank chart or ATG to determine height of <br />calculated volume <br />D Inches <br />803/8 <br />803/8 <br />801/4 <br />Measure top of fill riser threads, or face seal <br />adapter <br />E Inches <br />391/2 <br />393/4 <br />373/4 <br />Tank diameter (From Tank Chart) <br />F Inches <br />893/4 <br />893/4 <br />893/4 <br />Upper Tube in Tank (G) F -D = G <br />G Inches <br />93/8 if <br />9 3/8" <br />91/2 <br />Subtract 2" from upper tube in tank G.2"= K <br />K Inches <br />73/8 If <br />7 3/8" <br />71/2 <br />Calculated minimum upper tube length (I) <br />K+E=I <br />I Inches <br />463/4 <br />47" <br />451/2 <br />Actual measured upper tube length (Without <br />fill adapter) J <br />J Inches <br />481/2 <br />57 <br />55" <br />Certification Criteria Evaluation <br />Does the overfill prevention device meet the 95% <br />requirement? <br />Device Overfill Cert <br />Yes <br />Yes <br />Yes <br />Is the actual measured upper tube length 6.5 inches or <br />Yes <br />Yes <br />Yes <br />more than the fill riser? (J must be 6.5" or more than E) <br />Does the overfill prevention device function as required? <br />(Inspect the device for damage, contamination, freedom of <br />Yes <br />Yes <br />Yes <br />movement, weakening due to wear and corrosion <br />ification PASS /FAIL <br />Pass <br />Pass <br />Pass <br />Dro Tube Testin PASS /FAIL <br />Pass <br />Pass <br />Pass <br />Technician certifies that the device is operationally compliant. <br />Signature of Technician: <br />Technician's Name: Max Hines <br />��� Date: 10/1/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.