My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINDBERGH
>
5000
>
2300 - Underground Storage Tank Program
>
PR0232417
>
COMPLIANCE INFO_2017-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2022 9:31:32 AM
Creation date
6/23/2020 6:55:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0232417
PE
2361
FACILITY_ID
FA0003676
FACILITY_NAME
GRUPE COMMERCIAL COMPANY HANGER #2
STREET_NUMBER
5000
Direction
S
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 S LINDBERGH ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232417_5000 S LINDBERGH_2017-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br /> SANAAQUIN Environmental Health Department <br /> COUNT Y- <br /> 06ct n R 9rE <br /> Underground tor TaiProgram,- <br /> Facility Name: Facility Address: Date: <br /> GRUPE COMMERCIAL COMPANY HANGER#2 5000 S LINDBERGH ST, STOCKTON December 15, 2017 <br /> -aQ <br /> '--YST S Observations <br /> System I <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty o V o R o COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V c R c COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V ii R o COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V Ei R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V c R c COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V Ei R Ei COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms Ei V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ij V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements Ei V o R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements Ei V o R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system Ei V o R o COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump o V o R o COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards Li V Ei R o COS <br /> FZiinale4lil!alled kon-Pres razed 0i"joing <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R c COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed Ei V ii R ci COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) C]V Ei R ci COS <br /> Other Vio 4tions <br /> -7 2010See below Unlisted General violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MlOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate LIST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br /> where monitoring will be performed. Monitoring site plan was mising the general pipe layout and the location of the <br /> line leak detectors. Immediately log into the California Environmental Reporting System (CERS)at <br /> hftp://cers.calepa.ca.gov/and upload a copy of the LIST Monitoring Site Plan. <br /> This is a repeat violation, Class 11. <br /> FA0003676 PR0232417 SCOW 12/15/2017 <br /> EHD 23-01 Rev.10/31/2017 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.