Laserfiche WebLink
San Joaquin County AMENDED x <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone.(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.orp/ehd <br /> i <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: I Facility Phone: Date: <br /> GRUPE COMMERCIAL COMPANY HANGER 11''1 (209)473-6200 December 20,2016 <br /> Facility Address: CERS ID: <br /> 5000 S LINDBERGH ST, STOCKTON,CA 95206 10181293 <br /> Inspection Contact: Title: Phone: <br /> Maurice Liu Environmental Contact (209)484-5685 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST F_dRgA ' <br /> Consent For: Consent Given By: >' <br /> 0 Inspection 0 Photos 0 Samples Maurice Liu, Environmental Contact `` '�'`` ` <br /> Service Technician Onsite: Exp.Date: Designated Operator: 7 , Exp.Date: <br /> Zane Nimmo 06/1912017 Zane Nimmo '�' R 2'V08/26/2018 <br /> Service Technician Manufacturer's Training <br /> Tank Tester,03t31/19;VMI,02/03/17 <br /> CCR=L;alifomlaCodeofRegul8Uons HSC=Health and Safety Code CFR=Code of Federalegu a ions <br /> V=Violation = epe _ ` 494�: <br /> nngg Inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate o V o R o COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system o V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted u V a R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ■V ❑R ❑COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan ■V ❑R ❑COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan ■V ❑R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R u COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ❑V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days in V o R ❑COS E <br /> • E <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V ❑R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V a R n COS j <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ■V ❑R o COS <br /> i <br /> 1 <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V a R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days ❑V o R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V u R o COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after n V a R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests a V ❑R a COS <br /> 119 HSC 25299 Documents were falsified or misrepresented o V ❑R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V ❑R ❑COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V o R o COS <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored a V u R n COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ■V ❑R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V u R a COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site ❑V o R ❑COS <br /> FA0003676 PR0232417 SCO01 12/20/2016 <br /> EHD 23.01 Rev.09/22/16 Page 1 of 6 Underground Storage Tank Program OIR <br />