Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0232417
PE
2361
FACILITY_ID
FA0003676
FACILITY_NAME
GRUPE COMMERCIAL COMPANY HANGER #2
STREET_NUMBER
5000
Direction
S
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 S LINDBERGH ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232417_5000 S LINDBERGH_2017-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: βNIA <br /> Com ata the followin checklist: <br /> 0 Yes 0 No' Is the audible alarm operational? <br /> 0 Yes 0 No* Is the visual alarm operational? <br /> 19 Yes El No* Were all sensors visually Inspected,functionally tested,and confirmed operational? <br /> it Yes 0 No* Were all sensors Installed at lowest point of secondary containment and positioned so that other equipment will not Interfere with their proper <br /> operation? <br /> 0 Yes 0 No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operational? <br /> N/A <br /> 0 Yes β No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br /> β N/A falls to operate,or Is electrically disconnected? If yes:which sensors Initiate positive shut-down? (Check all that apply) 19 Sump/Trench <br /> Sensors; [I Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to teaksLnj sensor failure/disconnection? 0 Yes; 0 No. <br /> 0 Yes [3 No' For tank systems that utilize the monitoring system as the primary tank overfill warring device O.e.,no mechanical overfill prevention valve is <br /> N/A installed),Is the overfill warning alarm visible and audible at the tank fill point(s)and operating property? If so,at what percent of tank capacity <br /> I does the alarm trigger? % <br /> β Yes No Was any monitoring equipment replaced? if yes,Identify specific sensors,probes,or other equipment replaced and list the manufacturer name <br /> and model for all replacement parts In Section E,below. <br /> E]Yes* 0 No Was liquid found Inside any secondary containment systems designed as dry Systems? (Check 811 that 8PPIY) <br /> 0 Product; 0 Water. If yes,describe causes in Section E,below. <br /> 19 Yes [I No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,If applicable <br /> 0 Yes 0 No* Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> L <br /> ENVIRONMENTAL FEA-LTH <br /> DEFA MtN I <br /> Monitoring System Certification Page 2 of 4 2/21/07 <br />