FA0003676
FACILITY_NAME
GRUPE COMMERCIAL COMPANY HANGER #2
STREET_NUMBER
5000
Direction
S
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
5000 S LINDBERGH ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232417_5000 S LINDBERGH_1989-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WNIEFIED PROGRAM CONSOLIDATED <br />UNDERGROUNDSTORAGET ANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (one form per UST) <br />TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections 1, 11, 111, IV, and IX below) 430 <br />❑ 1. NEW PERMIT [] 3. RENEWAL PERMIT 0 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE 0 7. UST PERMANENT CLOSURE ON SITE [__1 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 410a I DATE EXISTING UST DISCOVERED: 430b <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) <br />N5TR, LLC 1, Hangar 2 <br />BUSINESS SITE ADDRESS 103 <br />CITY 104 <br />5000 South Lindbergh Street, Hangar 2 <br />Stockton <br />11. TANK DESCRIPTION <br />TANK ID # TA0241701 432 <br />TANK MANUFACTURER 433 <br />TANK CONFIGURATION: THIS TANK IS 434 <br />Owens Coming <br />®l . A STAND-ALONE TANK <br />El 2. ONE IN A COMPARTMENTED UNIT. <br />Complete one pNe for each comprurnent in the unit. <br />DATE UST SYSTEM INSTALLED 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS IN THE UNIT 437 <br />01/01/1989 <br />12,000 <br />111. TANK USE AND CONTENTS <br />TANK USE 0 Ia. MOTOR VEHICLE FUELING [I Ib. MARINA FUELING 1 c. AVIATION FUELING 439 <br />0 3. CHEMICAL PRODUCT STOP -AGE n 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)1 <br />[1 6. OTHER GENERATOR FUEL 0 95. UNKNOWN ❑ 99. OTHER (Specify): 439a <br />CONTENTS PETROLEUM: ❑ la. REGULAR UNLEADED E3 lc. MIDGRADEUNLEADED ❑ lb. PREMIUM UNLEADED 440 <br />❑ 3. DIESEL 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): 440a <br />NON -PETROLEUM: 0 7. USED OIL ❑ 10. ETHANOL <br />0 11. OTHER NON -PETROLEUM (Specify): 440b <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK [1 1. SINGLE WALL 19 2. DOUBLE WALL [_3 95. UNKNOWN 443 <br />PRIMARY CONTAINMENT 0 1. STEEL 0 3. FIBERGLASS 0 6. INTERNAL BLADDER 444 <br />[] 7. STEEL + INTERNAL LRQNG 0 95. UNKNOWN 0 99. OTHER (Specify): 444a <br />SECONDARY CONTAINMENT 0 1, STEEL 0 3. FIBERGLASS 0 6. EXTERIOR MEMBRANE LINER 0 7. JACKETED 445 <br />0 90. NONE El 95. UNKNOWN [199. OTHER (Specify): 445a <br />OVERFILL PREVENTION [1 1. AUDIBLE & VISUAL ALARMS 0 2. BALL FLOAT, 0 3. FILL TUBE SHUT-OFF VALVE 452 <br />0 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT / WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION 0 L SINGLE -WALLED 0 2. DOUBLE -WALLED 0 99. OTHER 460 <br />SYSTEM TYPE 0 LPRESSURE 0 2. GRAVITY 0 3. CONVENTIONAL SUCTION [1 4. SAFE SUCTION [23 CCR §2636(a)(3)] 458 <br />PRIMARY CONTAINMENT El 1. STEEL 0 4. FIBERGLASS [1 8. FLEXIBLE [:1 10. RIGID PLASTIC 464 <br />[1 90. NONE 0 95. UNKNOWN [1 99. OTHER(Specify): 464a <br />SECONDARY CONTAINMENT [1 1. STEEL 0 4. FIBERGLASS [1 8. FLEXIBLE 0 10. RIGID PLASTIC 4646 <br />[1 90. NONE 0 95. UNKNOWN [1 99. OTHER (Specify): 464c <br />PIPING/TURBINE CONTAINMENT SUMP TYPE [3 1. SINGLE WALL [1 2. DOUBLE WALL 0 90. NONE 464d <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT 1. STEEL [1 4. FIBERGLASS [1 10. RIGID PLASTIC n 90. NONE [1 99. OTHER (Specify) 464 <br />464el <br />VENT SECONDARY CONTAINMENT [2-1. STEEL [1 4. FIBERGLASS [I 10. RIGID PLASTIC FI 90. NONE [1 99. OTHER (Specify) 464f <br />464fl <br />VR PRIMARY CONTAINMENT ❑ LSTEEL [1 4. FIBERGLASS El 10. RIGID PLASTIC [1 90. NONE [1 99. OTHER (Specify) 4646 <br />464 <br />VR SECONDARY CONTAINMENT ❑ LSTEEL El 4. FIBERGLASS 0 10. RIGID PLASTIC [:1 90. NONE [1 99. OTHER (Specify) 464h <br />464h] <br />VENT PIPING TRANSITION SUMP TYPE Q 1. SINGLE WALL 0 2. DOUBLE WALL Q 90. NONE 4641. <br />RISER PRIMARY CONTAINMENT [j LSTEEL 0 4. FIBERGLASS n 10. RIGID PLASTIC 0 90. NONE El 99. OTHER (Specify) 76-41 <br />464il <br />RISER SECONDARY CONTAINMENT 0 LSTEEL [1 4. FIBERGLASS 0 10. RIGID PLASTIC [1 90. NONE 0 99. OTHER (Specify) 464k <br />464kI <br />FILL COMPONENTS INSTALLED 1. SPILL BUCKET El 3. STRIKER PLATE/BOTTOM PROTECTOR [1 4. CONTAINMENT SUMP 45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE ❑ 1. SINGLE WALL [1 2. DOUBLE WALL ❑ 3. NO DISPENSERS 90. NONE 469a <br />CONSTRUCTION MATERIAL 0 LSTEEL [1 4. FIBERGLASS 0 10. RIGID PLASTIC ❑ 99. OTHER (Specify) 469b -c <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) 0 4. IMPRESSED CURRENT 0 6. ISOLATION 448. <br />IX APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full compliance with legal requirements. 01 <br />APPLICANT SIGNATURELkz <br />DATE 12/8/2009 470 <br />APPLICANT NAME (print) JerryD. Irlart-Ir 471. <br />9F, <br />APPLICANT TITLEAviation Manager 472. <br />UPCF UST -B -1/2 Rev. (12/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.