My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2512
>
2300 - Underground Storage Tank Program
>
PR0232418
>
COMPLIANCE INFO_2009-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:12:54 PM
Creation date
6/23/2020 6:55:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2010
RECORD_ID
PR0232418
PE
2361
FACILITY_ID
FA0004064
FACILITY_NAME
WATERLOO LIQUOR
STREET_NUMBER
2512
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14128102
CURRENT_STATUS
01
SITE_LOCATION
2512 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232418_2512 E WATERLOO_2009-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
313
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, CA 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> ••�<<F OR��7 <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> Waterloo Liquors Monday, October 18, 2010 <br /> Facility Address: Service Request#t: <br /> 2512 E. Waterloo Rd., Stockton SR0061062 <br /> Onsite Service Technician's Name: ICC Service Technician/installer Exp.Date: Manufacturer Training: <br /> Steve Zwahlen 18025473UI 4/30/2012 Frankln 4443693761 10/29/2010 <br /> SERVICE SERVICE <br /> Leak detector <br /> ❑ mechanical Model: _Spill bucket ❑minimum 5 gallon <br /> ❑ ❑ electronic Serial#: ❑ ❑1 hour hydrostatic ❑Incon TS-STS <br /> ❑ line test programmed <br /> ❑Caldwell System ❑Other <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> ❑ ❑mechanical Model: ❑ ET—1hour hydrostatic ❑Incon TS-STS <br /> ❑electronic Serial#: ❑Caldwell System ❑Other <br /> ❑line test programmed <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> ❑mechanical Model: <br /> ❑ <br /> 13 electronic Serial#: ❑ ❑1 hour hydrostatic 13 Incon TS-STS <br /> ❑line test ammed ❑Caldwell System ❑Other <br /> sensor Primary piping testing at: <br /> ❑positive shutdown Model: <br /> ❑ <br /> 13 fail safe Serial#: ❑ minutes <br /> ❑NA <br /> sensor Secondary containment testing for: <br /> ❑ ❑positive shutdown Model: UDC(s) 87 Piping <br /> 13 fail safe Serial#: Sump(s) UST(s) <br /> ❑NA <br /> sensor Testing for the above components are next due by: <br /> positive sitive shutdown Model <br /> ❑fail safe Serial#: Note: Please be aware that 2°containment components are required to be tested upon <br /> ❑NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention(see LG letter 150-1) ❑ Other: see below <br /> -- Observed secondary containment test of the 87-octane fuel piping at 5 psi maintained for one hour <br /> post pouring of concrete on 10/13/2010. Passed. Permit condition of SR0061062 has been met. <br /> -- 87 and 91-octane UST product inventory levels were 1,872.73 and 1,064.42 gallons, respectively. <br /> Red Tag Significant Violation has been corrected; Red Tag has been removed from the two UST fill <br /> piping. UST System has returned to compliance and may resume operation. <br /> -- Observed Incon TS550 monitoring panel with incorrect time. CCR 2638 requires proper calibration <br /> of monitoring equipment to be tested and certified annually. Corrected on site by technician. <br /> THIS,FACAITY IS 4UMCT TO REINSPECTION T NY T1W A HD'S CURRENT HOURLY RATE. <br /> EHD Received B Tide: <br /> EHD 23-04 UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 06/01/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.