My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_1990-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 1:17:18 PM
Creation date
6/23/2020 6:55:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2003
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_1990-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED FO Ur <br /> �+® p� <br /> q + \ <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 TANKS <br /> VI.PIPING CONSTRUCTION(Check all that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE X 1. PRESSURE r 2. SUCTION r 3. GRAVITY F 1. PRESSURE F 2. SUCTION r 3. GRAVITY 459 <br /> CONSTRUCTION r 1. SINGLE WALL r 3. LINED TRENCH F 99. OTHER F 1. SINGLE WALL r 95. UNKNOWN 462 <br /> / X 2. DOUBLE WALL F 95. UNKNOWN F 2. DOUBLE WALL r99. OTHER <br /> MANUFACTURE <br /> R MANUFACTURER _ CTm tJ 461 MANUFACTURER 463 <br /> F 1.BARE STEEL F 6. FRP COMPATIBLE W1100%METHANOL F 1. BARE STEEL F 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND F 2. STAINLESS STEEL r 7. GALVANIZED STEEL F 2. STAINLESS STEEL F 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION r 3. PLASTIC COMPATIBLE WITH CONTENTS F 95. UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS F 8. FLEXIBLE(HDPE) F 99. OTHER <br /> X 4. FIBERGLASS F 8. FLEXIBLE(HDPE) F 99. OTHER r 4. FIBERGLASS F 9. CATHODIC PROTECTION <br /> F 5. STEEL W/COATING r 9. CATHODIC PROTECTION 464 F 5. STEEL WI COATING F 95. UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply). <br /> r 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR F 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS F 2. MONTHLY 0.2 GPH TEST <br /> F 2. MONTHLY 0.2 GPH TEST r 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> r 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> F 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY F 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM - <br /> TEST(0.1 GPH) r 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING). SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> F 7. SELF MONITORING F 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> r 9. BIENNIAL INTEGRITY TEST(0.1 GPH) F 8. DAILY VISUAL MONITORING <br /> F 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> F a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> X b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM r <br /> DISCONNECTION b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> F c. NO AUTO PUMP SHUT OFF r c. NO AUTO PUMP SHUT OFF <br /> X 11. AUTOMATIC LINE.LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR r 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> F 12, ANNUAL INTEGRITY TEST(0.1 GPH) F 12, ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> r 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS F 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> F 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND F 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> F 15, AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR F 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> r 16. ANNUAL INTEGRITY TEST(0.1 GPH) F 16 ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 17. DAILY VISUAL CHECK F IT DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT F 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE r 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 F 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS r 5. TRENCH LINER/MONITORING <br /> 2002 X 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS r 6. NONE 469 <br /> IX OWNERIOPERAIDIR SIGNATI IRE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIG NATU OF OWNER/QPERATO - DATE 1/15/02 470 <br /> NAME OF OWNER/OPERATOR(print) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Equilon Enterprises LLC PERMIT ANALYST 925-766-3498 <br /> Permit Number(For local use only) 473 1 Permit Approved(For local use only) 474 Permit Expiration Date(For local use only) 475 <br /> AOL <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.