My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_1990-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 1:17:18 PM
Creation date
6/23/2020 6:55:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2003
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_1990-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IIFIED PROGRAM CONSOLIDATED F <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> Cl <br /> >. VF PIP(Nfa QNSTR�JG'T E((�( �ftec�`att tlra annt <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE X 1. PRESSURE r 2. SUCTION r 3. GRAVITY r 1. PRESSURE r 2. SUCTION r 3. GRAVITY 459 <br /> CONSTRUCTION IF 1. SINGLE WALL IF 3. LINED TRENCH r 99. OTHER r 1. SINGLE WALL r 95. UNKNOWN 462 <br /> / X 2. DOUBLE WALL r95. UNKNOWN r 2. DOUBLE WALL r 99. OTHER <br /> MANUFACTURE <br /> R MANUFACTURER kw'64�90l) 461 MANUFACTURER 463 <br /> F 1.BARE STEEL r 6. FRP COMPATIBLE W/100%METHANOL r 1. BARE STEEL r 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND r 2. STAINLESS STEEL r 7. GALVANIZED STEEL r 2. STAINLESS STEEL r 7. GALVANIZED STEEL <br /> CORROSION r <br /> PROTECTION 3. PLASTIC COMPATIBLE WITH CONTENTS r 95. UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS r 8. FLEXIBLE(HDPE) r 99. OTHER <br /> X 4. FIBERGLASS r 8. FLEXIBLE(HDPE) IF 99. OTHER r 4. FIBERGLASS r 9. CATHODIC PROTECTION <br /> r 5. STEEL W/COATING r 9. CATHODIC PROTECTION 464 r 5. STEEL W/COATING 11-95. UNKNOWN 465 <br /> 77 7777,77 7,77,71 ' VII P1P��VGkE ( "17TGTIONTGizeraHs#h EapP�yfA 'P �#aflh mdrntorrngp`rvgrmpat#Zbe #ri7t/er #cataenc}� <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> r 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR r 1. ELECTRONIC LINE LEAK DETECTOR 3'.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK <br /> LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM�FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS r 2. MONTHLY 0.2 GPH TEST <br /> r 2. MONTHLY 0.2 GPH TEST <br /> r 3. ANNUAL INTEGRITY TEST(0.1 GPH) r 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> r 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> r 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY r 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) r 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> r 7. SELF MONITORING IF 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply). <br /> IF 9. BIENNIAL INTEGRITY TEST(0.1 GPH) r 8. DAILY VISUAL MONITORING <br /> r 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) <br /> F a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> X b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM r b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> r c. NO AUTO PUMP SHUT OFF r c. NO AUTO PUMP SHUT OFF <br /> X 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR r 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> r 12. ANNUAL INTEGRITY TEST(0.1 GPH) r 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> F 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS r 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> j EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> r 16. ANNUAL INTEGRITY TEST(0.1 GPH) r 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> r 17. DAILY VISUAL CHECK r 17. DAILY VISUAL CHECK <br /> i Vtll OIS(E SERO <br /> N,;, <br /> Me <br /> DISPENSER CONTAINMENT r 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE r 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 r 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS r 5. TRENCH LINER/MONITORING <br /> 2002 X 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS r 6. NONE 469 <br /> IX OWNERLOPERATOR SIrNAT1 IRF <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGNAT E,QF O ER/ ERATOR DATE 1/15/02 470 <br /> ee��)) 9 <br /> NAME OF OWNER/OPERAT R(print) 471 TITLE OF OWNERIOPERATOR 472 <br /> Bruce T. Marubashi for Equilon Enterprises LLC PERMIT ANALYST 925-766-3498 <br /> Permit Number(For local use only) 473 I Permit Approved(For local use only) 474 I Permit Expiration Date(For local use only) 475 <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.