Laserfiche WebLink
11FIED PROGRAM CONSOLIDATED F <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> r' Y[ F PIN�i CONS7REICTR <br /> n <br /> t /GhsckItthataPtF <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE X 1. PRESSURE r 2. SUCTION r 3. GRAVITY r 1. PRESSURE r 2. SUCTION r 3. GRAVITY 459 <br /> CONSTRUCTION r 1. SINGLE WALL r 3. LINED TRENCH r99. OTHER r 1. SINGLE WALL r95. UNKNOWN 462 <br /> / X 2. DOUBLE WALL r95. UNKNOWN F 2. DOUBLE WALL I 99. OTHER <br /> MANUFACTURE <br /> R MANUFACTURER /'$ L 461 MANUFACTURER 463 <br /> F 1.BARE STEEL r 6. FRP COMPATIBLE W/100%METHANOL I^ 1. BARE STEEL r 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND r 2. STAINLESS STEEL F 7. GALVANIZED STEEL 12. STAINLESS STEEL r 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION F 3. PLASTIC COMPATIBLE WITH CONTENTS F 95. UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS F B. FLEXIBLE(HDPE) 1199. OTHER <br /> X 4. FIBERGLASS F 8. FLEXIBLE(HDPE) r 99. OTHER r 4. FIBERGLASS r 9. CATHODIC PROTECTION <br /> I 5. STEEL W/COATING F 9. CATHODIC PROTECTION 464 r 5. STEEL W/COATING I'95. UNKNOWN 465 <br /> IJ <br /> ~„ 9fl11'I►Jr;lAK`DCTON(GtttatapPty}fst dtphaia€ n� n% > rartrsraN �cffithfgncyY ",rte<. <br /> ha } <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check al/that apply): - <br /> IF 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR'" I 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUTOFF FOR LEAK, " <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL,ALARMS <br /> ALARMS I 2. MONTHLY 0.2 GPH TEST <br /> F 2. MONTHLY 0.2 GPH TEST <br /> I' 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 3. ANNUAL INTEGRITY TEST(0.1 GPH) r 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> IF 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY I 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) T 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> IF 7. SELF MONITORING F 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> IF 9. BIENNIAL INTEGRITY TEST(0.1 GPH) F 8. DAILY VISUAL MONITORING <br /> F 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> Check one) <br /> Check <br /> a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> X b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM I b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> r c. NO AUTO PUMP SHUT OFF F c. NO AUTO PUMP SHUT OFF <br /> X 11. AUTOMATIC LINE,LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR I 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> I 12. ANNUAL INTEGRITY TEST(0.1 GPH) I 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> I 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS I 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> I 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR I 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> r 16. ANNUAL INTEGRITY TEST(0.1 GPH) r 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> I 17. DAILY VISUAL CHECK r 17. DAILY VISUAL CHECK <br /> r � UJB QfSPENSERGONrAiNfVINTf,. %5 y,.s :: r r r <br /> DISPENSER CONTAINMENT I 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE I' 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 F 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS IF 5. TRENCH LINER/MONITORING <br /> 2002 X 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS I 6. NONE 469 <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIG NATU OF OWNER/ RATO " DATE 1/15/02 470 <br /> n <br /> NAME OF OWNER/OPERATOR(print) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Equilon Enterprises LLC PERMIT ANALYST 925-766-3498 <br /> Permit Number(For local use only) 473 I Permit Approved(For local use only) 474 I Permit Expiration Date(For local use only) 475 <br /> 6 <br />