Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-(Pae I of 2) <br /> TYPE OF ACTION ❑1.NEW PLAN ® 2.CHANGE OF INFORMATION 49.j0-1 <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(�): <br /> FACILITY ID#(Agency Use Only) <br /> BUSINESS NAME(Same as FACILITY NAME) Grant Line Shell #136187 3• <br /> BUSINESS SITE ADDRESS 2375 W.Grant Line Road 103Y Tracy 104• <br /> 71 <br /> x '�;II 1:,QUI1VIEiVT;TES TANG AND•P]] EVETV�EVIAYNTEIYAIyGE.. <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> (23 CCR 2632,2634,2638,2641 <br /> ____-�-_ - _ _ ^--- ---- <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY M❑ 99.OTHER(Specify): 490-3A <br /> � I �ral,+Ir ttrii PII�JTdl l: IN< O 1 T 1 <br /> 1.NEW SITE PLOT PLANAVIAP SUBMITTED WITH THIS PLAN. <br /> Ttr`iot:$ <br /> ; <br /> ®2.SITE PLOT PLAN/i41AP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)490-4 <br /> .a:<�.s.• :,1 ( it ,r,�{ l� O` U I ,PERS R1VIE -fJ ING�rt'#Ik"' O >�;O Ir G!1VIETI <br /> elx ,.. a ✓ ttet*. ?rfl <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490.5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490-6 <br /> _PANEL MANUFACTURER: Veeder Root -�-490-7. MODEL#: TLS-350 _ <br /> -- LEAK SENSOR MANUFACTURER: Veeder Root - 490.9. MODEL#(S):- 794380-301 --- 990 to <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 490-12. MODEL#: 49043 <br /> IN_-TANK PROBE MANUFACTURER: 490'14- MODEL#(S): 490 Is <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS. --- - -❑ b.DAILY/NIGHTLY - ❑ c.WEEKLY 490-16 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17 <br /> h. ❑ b.0.2 h. ❑ c.OTHER(Specify): - -- -- - 49°-19 <br /> PROGRAMMED TESTS: ❑ a.0.l <br /> 8•P• g•P• fY)� 49919 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(IVITG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 4 0:22 <br /> ❑ 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490-23 <br /> 90- <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 425 <br /> ®99.OTHER (Specify): Simplicity 490-2649D-27 <br /> 9D 26 <br /> ro T Dg�( p �q( .�+ y'+. N('�M�+ ( \ 490-27 <br /> t ?F- .:4„.A,e9.f:: E7 u l 7a...,?1,t r- .y ,b°..,1"n+l�h' \..1. , ;:«:,y:..:•,'x! i k r�:'• <br /> V P L+f.` QNI GYS.`1'E F®RIVIED SIG H OL O I HODS Check allptftatapply);Af1reii :3i <br /> I.CONTINUOUS MONITORING OF PIPEt PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490-23 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS:®a.DRY ❑b.LIQUID FILLED [1c.PRESSURIZED ❑d.UNDER VACUUM 490-29 <br /> PANEL MANUFACTURER: Veeder Root 49MOD_EL#:_TLS-350 - 490.31 <br /> 010_ <br /> 4 - � - <br /> LEAK SENSOR MANUFACTURER: Veeder Root 90-]2- MODEL#(S): 794380-352,-208 499-33 <br /> - PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. - ®a.YES ❑b.NO 490.34 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ®a.YES ❑b.NO 490-35 <br /> 2.d1ECHANiCAL LINE LEAK DETECTOR(hHLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED(23 CCR§2636) -- - -_-__ 490-36 <br /> MLLD MANUFACTURER(S): _ 490-37 MODEL#(S): 490-38 <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-39 <br /> ELLD MANUFACTURERS} Veeder Root _ ---- - - - - 440'-._MODEL#(S):_PLLD-- _ -_ _ _ _ 4"47- <br /> ELLD <br /> 90 41 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g p.h. ❑ 2.MINIMUM ANNUAL 0.1 g p.h. 490•42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ®a.YES ❑b.NO 49043 <br /> ELLD FAILUREADISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ®a.YES ❑b.NO 49044 <br /> 4.PIPE INTEGRITY TESTING 49045 <br /> TEST FRE UENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER S eci 490.4649047 <br /> 5.VISUAL PIPE MONITORING. 490.49 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY r2 EACH TIME SYSTEMOPERATED* 490.49 <br /> •Allowed for monitorin of unburied emergency aerator fuel pipi.g ordy pa NSC 25231.5 3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(a)(3)1. 490-50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490.51 <br /> ❑ 99.OTHER(Specify) 49992 <br /> 990-91 <br /> UST Response Plan(312008)3/3 <br />