COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APR-06-2009 12:3? Service Station Systems 408 938 8888 P.03 <br /> Veeder-Root 0 0 Pagel of <br /> Lsm Datet. Ugust 28,1998 <br /> RevWton Date:3ufm 20,2008 <br /> Veeder-Root <br /> TILS-300,30011,TLS-350 Series,TLS-450 Series, Red 3acket ProMax and Proplus with <br /> Discriminating Dispenser Pan Sensor 794380-322, <br /> Discriminating Containment Sump Sensor 794330-352 <br /> INTERSTMAL DETECTOR(UQUID-PHASE) <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle; product permeable, reed switch/float <br /> Test Results: <br /> pgly�erstr�! float switch <br /> jLnleaded,gasoline diesel wader <br /> Discriminating Dispenser Pan high* low* <br /> Sensor 7943 - <br /> 80322 - <br /> Response time(sec) -10 min 2-12 hrs <1 <1 <br /> Recovery time(sec) N/A** N/A <1 <1 <br /> Lower detection limit- height(in) N/D** N/D 7.66 1.37 <br /> Lower detection limit-thickness (in) 0.005 0.005 N/A N/A <br /> Discriminating Containment Sump <br /> Sensor 794380-352 - - <br /> Res nse <br /> Response time(sec) -10 min 2-12 hrs <1 <1 <br /> Recovery time(sec) 17.2 min N/A <1 <1 <br /> Lower detection limit- height(in) N/D N/D 12.28 1.35 <br /> Lower detection limit-thickness (in) 0.005 0.005 N/A N/A <br /> *The"high" and "low" refer to high and low level alarm points of float switch sensors. <br /> ** See glossary. <br /> Specificity Results(in addition to above): <br /> Activated; synthetic gasoline, jet-A fuel, n-hexane, toluene, xylene(s) <br /> Not activated: water(polymer strip only) <br /> Comments: <br /> Polymer strip must be air dried after exposure to unleaded fuel. <br /> Polymer strips must be cleaned with solvent and dried after exposure to diesel, <br /> Comparison of TLS-450 with TLS-350 series console showed comparable results when evaluated with <br /> representative sensors. <br /> Veeder-Root Evaluator: Ken Wilcox Associates <br /> 125 Powder Forest Dr. Tel: (816)443-2494 <br /> Simsbury, CT 06070-2003 Dates of Evaluations, 01/02195, 06/23/97, <br /> littn://www.nwelde.orp-/evals/veeder root o.litinl 4/6/09 <br />