My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 4:12:21 PM
Creation date
6/23/2020 6:56:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o�qurN• c <br />• San Joaquin County AMENDS <br />Environmental Health Department <br />Y. 1868 East Hazelton Avenue, Stockton, CA95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sogov.org/ehd <br />atl i16 `* <br />Underground Storage Tank Program Compliance Review Report <br />Facility Name: <br />Facility Phone: <br />Date: <br />GRANT LINE SHELL* <br />(209) 836-8908 <br />April 24, 2018 <br />Facility Address: <br />CERS ID: <br />2375 W GRANT LINE RD, TRACY, CA 95376 <br />10181399 <br />Inspection Contact: <br />Title: <br />Phone: <br />VIOLATIONS: <br />The following non -inspection related violations listed below from the California Health and Safety Code (HSC), California <br />Code of Regulations (CCR) and/or the Code of Federal Regulations (CFR) were found. <br />#101 HSC 25284 Failure tai obtain a valid permit to operate from the EHD including but not limited to unpaid. fees <br />OBSERVATIONS: Due to a failed routine secondary containment testing, violations have been issued and a 2018 permit <br />to operate the UST system has not been issued. No person may own or operate an UST unless a permit for its operation <br />has been issued by the local agency to the owner or operator of the UST system. Immediately obtain a permit to operate a <br />UST system from the EHD. An "Operating without a Permit" penalty applies. <br />This is a Class I violation. <br />#121 CCR 2712(f) ;Failed to submit a. written response within 30 days of receiving an inspection report <br />OBSERVATIONS: An inspection was last done on March 21, 2017 and an inspection report was issued identifying <br />information to be submitted to bring this site into compliance. This information was required to be submitted within 30 days <br />of receiving the inspection report. This information has not been received resulting in a non-compliant status for this <br />facility. An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br />response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />This is a repeat violation, Class II. <br />#314 HSC 25290.1, 252911Y:2; 25291 Failed to have secondary,containment or secondary containment not tight <br />OBSERVATIONS: The April 12, 2017 secondary containment test results indicate a failure at the diesel secondary <br />product, 87 secondary product, 89 secondary product, 91 secondary product, all turbine sumps, and UDCs 1/2, 3/4, 9/10, <br />11/12, 15/16, 17/18, 19/20, 21/22. All secondary containment for the UST system must be tight. To date, no repairs have <br />been made. Immediately have a properly licensed, trained, and certified contractor repair or replace the failed component <br />under permit and inspection of the EHD. <br />This is a minor violation. <br />T <br />OVERALL NOTES AND COMMENTS .. <br />This UST program compliance review report was provided to the facility operator on 4/24/2018. The report was amended <br />by the EHD on 6/25/2018. The amended report replaces the initial report. <br />Violation #109- Failed to test secondary containment. Was removed from the previous inspection report. The other <br />violations cited in this report stand and should have been corrected within 30 days of the initial report. <br />FA0003772 PR0232469 SCO21 04/24/2018 <br />Rev. 01/08/16 Page 1 of 2 Underground Storage Tank Program Compliance Review Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.