Laserfiche WebLink
4 <br />RANT LINE SHELL* CERS ID <br />375 W GRANT LINE RD 10181399 <br />RACY, CA 95376 Tank ID#: 1 <br />a <br />Ma, ..,. <br />ubmitted on 5/16/2018 by Gina (Pimentel) Compigli of RADC Enterprises Inc. (Upland, CA) <br />omments by submitter: Corrections made per inspection report dated 5/15/2018 <br />Type of Action (UST Tank) <br />Confirmed/Updated information <br />y <br />h� <br />RANT LINE SHELL" <br />375 W GRANT LINE RD <br />RACY, CA 95376 <br />Tank ID# Date UST System Installed Tank Configuration <br />6/6/1991 A Stand-alone Tank <br />Tank Manufacturer Date Existing UST Discovered Number of Compartments in the Unit <br />ERXES 1 <br />Tank Capacity In Gallons Date UST Permanently Closed Additional Description <br />2000 <br />rank Use Tank Contents <br />Motor Vehicle Fueling Regular Unleaded <br />Other Petroleum Contents <br />Other Non -Petroleum Contents <br />iping Construction a�z �SPrimary Containment Secondary Containment Pipinourbine Containment Sump <br />oubie-walled I Fiberglass ( Fiberglass Single -waited <br />iping System Type <br />ressure <br />...sr_. s ...£.,,, W <br />Primary Containment Vapor Recovery Primary Containment Riser Pipe Primary Containment Vent Piping Transition Sumps <br />Fiberglass Fiberglass Steel None <br />Fill Components Installed <br />Secondary Containment Vapor Recovery Secondary Containment Riser Pipe Secondary Containment Yes Spill Bucket <br />None None Fiberglass Yes Striker Plate/Bottom Protector <br />Yes Containment Sum <br />onstruction Type Construction Material Sacrificial Anode <br />ingie-walled Fiberglass Impressed Current <br />Yes isolation <br />Printed on 5/16/2018 8:35 AM <br />Type of Tank <br />Double Wali <br />Primary Containment <br />Secondary Containment <br />Fiberglass <br />Fiberglass <br />Dverfill Protection <br />Audible/Visual Alarms <br />Fill Tube Shut -Off Valve <br />Yes Ball Float <br />Exempt <br />iping Construction a�z �SPrimary Containment Secondary Containment Pipinourbine Containment Sump <br />oubie-walled I Fiberglass ( Fiberglass Single -waited <br />iping System Type <br />ressure <br />...sr_. s ...£.,,, W <br />Primary Containment Vapor Recovery Primary Containment Riser Pipe Primary Containment Vent Piping Transition Sumps <br />Fiberglass Fiberglass Steel None <br />Fill Components Installed <br />Secondary Containment Vapor Recovery Secondary Containment Riser Pipe Secondary Containment Yes Spill Bucket <br />None None Fiberglass Yes Striker Plate/Bottom Protector <br />Yes Containment Sum <br />onstruction Type Construction Material Sacrificial Anode <br />ingie-walled Fiberglass Impressed Current <br />Yes isolation <br />Printed on 5/16/2018 8:35 AM <br />