My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 8:57:40 AM
Creation date
6/23/2020 6:56:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Environmental Reporting System (CERS) Underground Storage Tank - Monitoring Plan <br />,NT LINE SHELL* <br />W GRANT LINE RD <br />Y, CA 95376 <br />Continuous Monitoring of Piping Secondary Containment <br />g Secondary Containment Panel Manufacturer <br />Veeder Root <br />Panel Model # <br />TLS -350 <br />Leak Alarm Triggers Automatic Pump Shutdown <br />Failure/Disconnect Triggers Pump Shutdown <br />Mechanical Une Leak Detector Performs 3 GPH Leak Test <br />1 Manufacturer MLLD Model <br />Electronic Line Leak Detector Performs 3 GPH Leak Test <br />Manufacturer ELLD Programmed In -Line Testing <br />ler Root 0.2 GPH <br />Model <br />UST Tank # CERS ID <br />2 10181399 <br />Tank Info: Installed Date: 6/6/199112:00:00 AM -Tank Use: Motor Vehicle Fueling -Tank <br />Contents: Midgrade Unleaded -Type Of Tank: Double Wall - Piping Construction: Double - <br />walled <br />Leak Sensor Manufacturer <br />Veeder Root <br />Leak Sensor Model # <br />794380-352/208 <br />ELLD Triggers Automatic Pump Shutdown <br />Yes <br />ELLD Failure/Disconnect Triggers Automatic Shutdown <br />184 Yes <br />Pipeline Integrity Testing Visual Pipeline Monitoring <br />peline Integrity Testing Frequency Visual Pipeline Monitoring Frequency <br />Suction Piping Meets Exemption Criteria <br />No Regulated Piping Per Health and Safety Code, Division 20, Chapter 6.7 Is Connected To The Tank System <br />Other Pipeline Monitoring <br />JDC Monitoring <br />Detection of Leak into UDC Triggers Audible and Visual Alarms <br />:ontinuous <br />Yes <br />UDC Leak Alarm Triggers Automatic Pump Shutdown <br />JDC Panel Manufacturer <br />Yes <br />feeder Root <br />Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br />JDC Panel Model # <br />Yes <br />rLS 350 <br />UDC Monitoring Stops Flow of Product at Dispenser <br />JDC Leak Sensor Manufacturer <br />feeder Root <br />UDC Construction <br />JDC Leak sensor Model <br />Single -walled <br />794380-208 <br />UDC Secondary Containment Monitoring <br />Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br />ELD Testing <br />Yes Secondary Containment Testing <br />Yes Spill Bucket Testing <br />Printed on 5/16/2018 8:36 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.