My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
121
>
2300 - Underground Storage Tank Program
>
PR0232594
>
COMPLIANCE INFO_1992-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 12:53:22 PM
Creation date
6/23/2020 6:56:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2005
RECORD_ID
PR0232594
PE
2361
FACILITY_ID
FA0004573
FACILITY_NAME
SJ COUNTY PARKING GARAGE
STREET_NUMBER
121
Direction
S
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
14912001
CURRENT_STATUS
01
SITE_LOCATION
121 S SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232594_121 S SAN JOAQUIN_1992-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB. January 2002 <br />4. TANK ANNULAR TESTING <br />Page 2 of 7 <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for tailed tests) <br />REPAIRED RISER (REPLACED RISER) RETESTED 10 HG AFTER BACKFILLING RISER <br />AND BACKFILLING RISER PIPE BOTH TESTS DONE AT 10 HG VACUUM, NO DROP ON <br />EITHER TEST. <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems <br />that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment testing. {California Code of Regulations, Title 23, <br />Section 2637(a)(6)] <br />Tank # 1 <br />Tank # <br />Tank # <br />Is Tank Exempt From <br />Testing? 1 <br />[ ] Yes [X] No <br />[ ] Yes [ ] No <br />[ ] Yes [ ] No <br />Tank Capacity: <br />10,000 -GALLON <br />Tank Material: <br />FIBERGLASS <br />Tank Manufacturer: <br />XERXES <br />Product Stored: <br />UNLEAD GAS <br />Wait time between <br />applying <br />pressure/vacuum/water <br />and starting test: <br />10 MINUTES <br />Test Start Time: <br />11:50 A.M. 1. 16.03 <br />Initial Reading (Rl): <br />10 HG <br />Test End Time: <br />1:00 P.M. 1. 16.03 <br />Final Reading (Rf): <br />10 HG <br />Test Duration: <br />1 HOUR, 10 -MINUTES <br />Change in Reading (Rf- <br />R1 <br />-0- <br />Pass/Fail Threshold or <br />Criteria: <br />Less than 2 HG drop in one <br />hour <br />Test Result: <br />IX] PASS 1, ] 'FAIL <br />I ] PASS I ]TAIL <br />[ ] PASS [ ] FAIL <br />Was sensor removed for <br />testing? <br />[X] YES [ ] NO <br />[ ] N/A <br />[ ]YES [ ] NO <br />[ ] N/A <br />[ ] YES[ ] NO <br />[ ]N/A <br />Was sensor properly <br />replaced & verified <br />functional after testing? <br />[X]YES [ ] NO <br />[ ] N/A <br />[I YES [ ] NO <br />[ ] N/A <br />[ ] YES [ ] NO <br />[ ] N/A <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for tailed tests) <br />REPAIRED RISER (REPLACED RISER) RETESTED 10 HG AFTER BACKFILLING RISER <br />AND BACKFILLING RISER PIPE BOTH TESTS DONE AT 10 HG VACUUM, NO DROP ON <br />EITHER TEST. <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems <br />that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment testing. {California Code of Regulations, Title 23, <br />Section 2637(a)(6)] <br />
The URL can be used to link to this page
Your browser does not support the video tag.