My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
121
>
2300 - Underground Storage Tank Program
>
PR0232594
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 3:21:31 PM
Creation date
6/23/2020 6:56:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0232594
PE
2361
FACILITY_ID
FA0004573
FACILITY_NAME
SJ COUNTY PARKING GARAGE
STREET_NUMBER
121
Direction
S
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
14912001
CURRENT_STATUS
01
SITE_LOCATION
121 S SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232594_121 S SAN JOAQUIN_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
313
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jul ?1 08 04:27p 209-367-5424 p.4 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-PAGE 2 <br /> VI.DISPENSER MONITORING <br /> MONT'ORING OF AREAS BENEATH DISPENSER(S)IS PERFORMED USING THE FOLLOWING NIETHOD(S)(Check all that apply) SOO. <br /> [S�I CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANEL MANUFACTURER: V»SOI A-R M51' MODEL#: R'b.S-3S� M5z <br /> LEAK SENSORMANUFACTURER: Mme- MODELA(S):_ 2OR M54. <br /> WILL DETECTION OF ALEAK INTO TETE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? a YES ❑ b.;\TO M55. <br /> %M L A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? �9a.YES <br /> '#%'ILL FAILUREtD1SCONNECUON OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC P[Ae SHUTDOWN? )�'a.YES ❑ b.NO 1AS7 <br /> ❑ 7-MECHANICAL ASSEMBLY(e.g.,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE W CASE OF LEAK <br /> ASSEMBLY MAINUFACI'URER: MS& MODEL,-,(S)C M59. <br /> ❑ 3.VISUAL MONITORING DONE: ❑ a.DAILY ❑ Is.WEEKLY(Regains age w wpm W) MG(X <br /> ❑ 4.NO DISPENSERS <br /> ❑ 99.OTHER(Specify) Mfi1. <br /> . ENHANCED LEAK DETECTION <br /> ❑ 1.WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES COIN'TRCL•BOARD THAT WE MUST IMPLEMENT EAT-LANCED LEAK a�' <br /> DETECTION(ELD)FOR TIS UST(S)COVERED BY THIS PLAN.PER 23 CCR§2644.I.ELD IS PERFORMED EVERY 36 MO\''THS AS REQUIRED <br /> VIII. TRAINING <br /> RFFRRR DOCUMENTS MAINTAINED AT FACILITY(Chock aff that apply) M80. <br /> 1. S UNDERGROUND STORAGE TANK MONITORING PLAN(Req aired) <br /> 2. ' PERMING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3. [r THE FACILITY'S BEST MA NAGl?MMNf PRACTICES(Required as of I101n905) <br /> 4. [-'^CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> b. STATE �A7ATER.RESOURCES CONTROL BOARD (SWRCB) PUBLICATION:"HANDBOOK FOR TANK OWNERS -MAN[AL AND <br /> STATISTICAL INVENTORY RECONCILEATION" <br /> 7. ❑ SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE.TANKS" <br /> 99.❑ OTFIFR(Specify): Nest. <br /> Personnel with UST monitoring respotutbilities ane famma"barwith all ofthe above documents relevautto their job duties and can access those documents when needed <br /> By January I,2005 this facility will have a"Designated UST Operatoe"who hank passed&L operator exam administered by the International Coda Codi(ICC). By <br /> January 1,2005,and annually thereafter,the "Designated UST Operator"will traits facility employees in the proper operation and maintenance of the UST systems. <br /> This training will include,but is not limited to,the following: <br /> 'e Operation of the UST systems in a summer consistent with the facility's best management practices. <br /> ➢ Ila facility employee's role with regard to the leak detection equipment. <br /> Y The facility empbyee's role with regard to spills and ovc&lis. <br /> ➢ Whom to contact for emergencies and leak detection alarms. <br /> For facility employ ots hired eta or after January 1,2005,the initial training will be conducted within 30 days of the data of hire. <br /> LY. CO MENTSIADDITIONAL INFORMATION <br /> Please use this section to include any additional UST system monitoring-related information(e.g.,additional information requked by your local agency): utas. <br /> 11) tJLQ,PXL&. =S padav-zoteb ey Ara op"I 4150 c�I�tt. Ca1a.t r <br /> �..' Otit PRej s'S At-Sim vagpdAmea Sy MU® A r'7'1'1€ vlesoetReft <br /> TL-S+-3,T0 6L C-10-SI-S. 9 09"1-4- <br /> X. PERSONNEL RESPONSIBILITIES <br /> AS OF 111105, THE`DESIGNATED UST OPERATOR IDENTIFIED IN SECTION III OF THE CURRENT UST OPERATLNG PERN TT APPLICATION- <br /> FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACl'IVTTJES AND MAINTAINING LEAK DEIMCTION <br /> EQUIPMENT COVERED BY TkHS PLAN,ARID WILL PERFORM AND DOCUMENT MINMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br /> UST SYSTEMS IN ACCORDANCE WITH 23 CCR§2715(b} <br /> XI. i/OPERA.TOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the crest of ml knowled <br /> PERATOR SIG TUR$ REPRESENTING DATE: MI. <br /> ❑Owner M90 &,vA.,f ZGor <br /> for <br /> OPERATOR AME(print)_ A29z OPERATOR"flTLE: j)eSLTa,0-J °L <br /> J'as EPN IBA y LAWATAGAGWOJ6 <br /> (Agency Use Only) This plan has boon reviewed and Apprm od ❑Approved With C.WMons ❑rr�� pproved <br /> Disa <br /> OSLocal Agency Signature: Ann Date: � oJ' <br /> v <br /> Comments/Special Conditions: <br /> SJCEHD-d(07/03)-314 07/23103 <br />
The URL can be used to link to this page
Your browser does not support the video tag.