Laserfiche WebLink
G ,v.'vnv v 4 33r. <br /> STATE OF CALIFORNift WATER RESOURCES CONTR <br /> FORM 'B': UNDE ROUND STORAGE TANK PRO <br /> ARD <br /> AM "' <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. a <br /> MARK ONLY ❑ NEW PERMIT r-13 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM u ` INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED ~Z <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 1663;' Q Q J (j�--- FARM TANK-YES❑ NO <br /> 1. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY { I <br /> A. OWNERS TANK ID# / B. MANUFACTURED BY: I//f <br /> C. YEAR INSTALLED U D. TANK CAPACITY IN GALLONS: fFJ (�Q O <br /> W <br /> II. TANKONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED OMPLETE ITEM D. 00 <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.,# C.A.S.#: <br /> x111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM W2SINGLE ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ <br /> MATERIAL 5 CONCRETE ❑6 POLYVINYL CHLORIDE n 7 ALUMINUM El 100%METHANOL COMPATIBLE FRP <br /> ���/J� <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑99 OTHER <br /> . ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY LINING 4 YHENOLIC LINING <br /> C.INTERIOR <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> h <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT n 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br />`r <br /> A.SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE <br /> C.MATERIAL A U 5 ALUMINUM A 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> j P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> V1. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> GALLONS <br /> I THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> i <br /> r LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> f <br /> -1 <br /> ., I I <br /> a 2 D o <br /> FPq L It CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> ' 1 9-/f---yr <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# SY: <br /> f FORM B(3-7-88) THIS FORM MUST BE ACCOMPANI Y A FACILITY/SITE APPLICATION, FORM'A',UNLESS RRENT FORMA' HAS BEEN FILED <br />? DATA PROCESSING COPY , <br />