My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2000-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:31:54 PM
Creation date
6/23/2020 6:56:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2007
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504388_1605 S EL DORADO_2000-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r , IWIED PROGRAM CONSOLIDATED FORM TANK: TA0505633 <br /> PR#: PRO504388 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 FAC#: FA0006185 <br /> (two pages per tank) <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMITPage 4 of 5 <br /> ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Cheek only item only) <br /> Y�>i E'� �� _ I"� (t�t i �'�`y Y ��" "`I"tt' ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT i ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: I <br /> I MAR -r*' 3 FA0006185 PR0504388 <br /> LOCATION WITHIN SITE(Option) 1605 S EL DORADO ST,STOCKTON 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Owners Tank ID#: 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ❑No 434 <br /> Z-YA690§633 TRUSC O If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 4/17/1995 8,000 <br /> ADDITIONAL DESCRIPTION(For local use only) <br /> 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1.MOTOR VEHICLE FUEL ® 1 a.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked complete Petroleum Type) <br /> ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAMEM <br /> d <br /> H <br /> from azarous Materials Inventory a <br /> ( ry e P g) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑ 4.HAZARDOUS WASTE <br /> (Imludm Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ S.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> 08 <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑ 3.EPDXY LINING 447 <br /> OR COATING ❑ 5.GLASS LINING ❑95.UNKNOWN aab DATE INSTALLED <br /> (Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑6 UNLINED ®99.OTHER <br /> STEEL (For local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ❑ I SPILL CONTAINMENT 1,995.00 1 ALARM <br /> ❑ 2 DROP TUBE ❑ ❑ 3 FILL TUBE SHUT OFF VAL <br /> ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ass ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.