My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:37:30 PM
Creation date
6/23/2020 6:56:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504388_1605 S EL DORADO_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />'jgg' g <br />Facility Name: <br />MIRAMAR ENTERPRISES <br />Facility Phone: Date: <br />(209) 939-1906 May 09 2016 <br />Facility Address: CERS ID: <br />1605 S EL DORADO ST, STOCKTON, CA 95206 10182043 <br />Inspection Contact: <br />Balajai Angle <br />Title: <br />Owner I <br />Phone: <br />Inspection Type: I <br />ROUTINE INSPECTION - Operating Permit <br />-Program: <br />12361 - UST FACILITY <br />Consent For: I Consent Given By: <br />Z Inspection 21 Photos Z Samples I Balajai Angle, Owner <br />Service Technician Onsite: Exp. Date: <br />David Winkler 03/01/2018 <br />Designated Operator: Exp. Date: <br />Karen Arnaiz 05/05/2017 <br />Service Technician Manufacturer's Training <br />Tank Tester,03/31/17; Veeder-Root, 02/03/18; VMI Tester, 11/02/17 <br />CCR =California Code of Regulations HSC =Health and Safety Code CFR =Code of Federal Regulations <br />V = Violation R =Repeat violation COS= Corrected on site during inspection <br />101 <br />HSC 25284 <br />No permit to operate <br />o V o R o COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V o R o COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />c) V Ei R o COS <br />104 <br />CCR 2711 <br />UST Operating Permit Application for Facility and Tank information not submitted or current <br />m V m R ii COS <br />105 <br />HSC 25286(c) <br />Current BOE number not submitted <br />o V o R Ei COS <br />106 <br />CCR 2632 <br />Monitoring and response plans not current or approved by the EHD <br />m V m R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />w V m R o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />Ei V ii R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />o V Ei R o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />ii V o R c COS <br />ill <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />Ei V o R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />Ei V o R o COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />o V o R Ei COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />ii V ii R o COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />o V o R c COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />o V [3 R o COS <br />117 <br />HSC 25292.5 <br />Failed to conduct ELD testing on a system located within 1000' of a public well <br />Ei V o R Ei COS <br />118 <br />HSC 25292.5 <br />Failed to repair and retest system due to failed ELD test <br />o V iD R c COS <br />119 <br />CCR 2644.1(a)(5) <br />Failed to submit ELD test results within 60 days <br />o V Ei R c COS <br />120 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />Ei V Ei R u COS <br />121 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />Ei V ii R Ei COS <br />122 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />o V o R c COS <br />123 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />o V o R c COS <br />124 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />Ei V o R o COS <br />125 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />n V o R o COS <br />126 <br />HSC 25404(e)(4) <br />Failed to report program data electronically <br />m V m R o COS <br />Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.