My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:37:30 PM
Creation date
6/23/2020 6:56:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504388_1605 S EL DORADO_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 5 <br />0 0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: wvtw.sffiqov.orq/ehd <br />Facility Name: <br />Facility Address: <br />Date: <br />MIRAMAR ENTERPRISES <br />1605 S EL DORADO ST, STOCKTON <br />May 09, 2016 <br />< <br />MEMO, <br />11ryes <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />0 V 13 R <br />❑ COS <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />Ei V c R <br />Ei COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />m V m R <br />■ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />o V o R <br />❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />ii V Ej R <br />o COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />Ei V o R <br />o COS <br />327 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />o V o R <br />o COS <br />328 <br />HSC 25283.5 <br />Unburied below grade LIST failed to meet exemption status <br />o V o R <br />o COS <br />329 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V o R <br />o COS <br />330 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />Ei V Ei R <br />Ei COS <br />331 <br />HSC 25299(0(2) <br />Tampered with or disabled leak detection devices or alarms <br />o V Ei R <br />o COS <br />332 <br />CCR 2631.1 <br />LIST system not compatible with the substance stored <br />o V Ei R <br />Ei COS <br />333 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />o V o R <br />o COS <br />334 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />o V o R <br />o COS <br />MIMI <br />=12 <br />W. <br />M� <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V o R <br />o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />ci V o R <br />o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />11 V o R <br />c COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />Ei V o R <br />o COS <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />Ei V o R <br />u COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />Ei V Ei R <br />Ei COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ci R <br />❑ COS <br />Item # <br />Remarks <br />104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information forms for the 87 and 91 tanks are not current in CERS. The 'piping construction' section was <br />left blank on both tank forms. Any change of information must be updated in CERS within 30 days of the changes. <br />Immediately log into CERS, update the required information, and submit for review by the EHD. <br />This is a repeat violation, <br />Class 11. <br />Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.