My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2002-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 1:24:55 PM
Creation date
6/23/2020 6:56:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2004
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2002-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAN-1-2002 04:19P FROM: T :12094683433 P:6/8 <br /> F. in-Tank Gauging/SYR Equipment: Iff Check this box if tank gauging is used only for inventory control. <br /> Cl Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank g$tiging equipment is used to perform leak detection monitoring. <br /> Complete the followin checklist: <br /> ❑ Yes ❑ No* Iias all input wiring;been in ted for proper entry and termination.including testing for ground faults? <br /> ❑ Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> ❑ Yes ❑ Not- Was accuracy of system produ�:, level readings tested? <br /> U Yes ❑ No* Was accuracy of system water 1�!vel readings tested? <br /> ❑ Yes ❑ No* Were all probes reinstalled properly? <br /> ❑ Xes ❑ No* Were all items on the cquipmeit manufacturer's maintenance checklist completed? <br /> * <br /> In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line i.eatk Detectors(LLD): Q Ct,mk.this box if L,L.ns are not installed. <br /> Com lets the following checklist: <br /> L'l Yes U No* For equipment start-up or angital equipment "wtitication, was a leak simulated to verify LLD performance? <br /> ❑ N/A (Check all that apply) Simulat;,d leak rate: ❑i g.p.h.; ❑0.1 g,p.h; ❑0.2 g.p.h_ <br /> ❑ Ycs Q No Were all LLDs confirmed oper;t tional and accurate within regulatory requirements? <br /> ❑ Yes 1 ❑ No* Was the testing apparatus prorxrly calibrated? <br /> ❑ Yes ❑ No* For mechanical LLDs,does thl LLD restrict product flow if it detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No* For electronic LLDs.does the tarbine automatically shut off if the LLD detects a leak? <br /> ❑ N/A <br /> U Yes U No* For electronic LLDs,does the ti trbinc automatically shut off if any portion or the monitoring;system is disabled <br /> ❑ N/A or disconnected? <br /> ❑ Yes ❑ No* For electronic LLDs, does --I;e turbine Automatically shut off if any portion of the monitoring system <br /> ❑ N/A malfunctions or faits a test'.? <br /> ❑ Yes ❑ No* For electronic LLDs,have all a;ecssible wiring connections been visually inspected'? <br /> ❑ N/A <br /> U Yes ❑ No* Were all items orf the cQuipm=I manufacturer's maintenance checklist eompleted'l <br /> "In the Section H,below,describe how and whit these deficiencies were or will be corrected. <br /> Fk. Comments- <br /> Page 3 of 3 ort <br />
The URL can be used to link to this page
Your browser does not support the video tag.