My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2005-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 1:40:04 PM
Creation date
6/23/2020 6:56:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2007
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2005-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
348
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,I MINSHINANNIMM <br /> Issue Date:November 22,1995 <br /> Revision Date:November 14,1997 <br /> Vaporless Manufacturing <br /> Vaporless LD-2000, LD-2000S <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph with PD = 100% and PFA = 0%. <br /> Leak 1.7 gph. <br /> Threshold A pipeline system should not be declared tight if the test result indicates a loss that <br /> equals or exceeds this threshold. <br /> Applicability Gasoline, diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized fiberglass or steel pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum of 129 gallons. <br /> Capacity <br /> Waiting Time None between dispensing and testing. <br /> None between delivery and testing. <br /> Test Period Response time is 5 seconds. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> LD2000 - restricted flow to dispenser if leak is declared. <br /> LD2000S - pump shutoff if leak is declared. <br /> Calibration Equipment must be checked annually for capability of detecting a line leak of <br /> 3.0 gph and, if necessary,calibrated in accordance with manufacturer's <br /> instructions. <br /> Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br /> 8700 East Long Mesa Drive Tel: (816) 443-2494 <br /> Prescott Valley,AZ 86314 Dates of Evaluation: 11/19/90 <br /> Tel: (520) 775-0185 <br /> I Home I Vendors;..A-F I Vendors_.G_-M I Vendors:_N-S I Vendors: T-Z I Method.._Index.I <br /> http://www.swrcb.ca.gov/cwphome/Ust/leak-prevention/lgl BNendor_Files/vaporless_manuf... 8/8/05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.