My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 EVR PHASE II UPGRADE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2008 EVR PHASE II UPGRADE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 1:55:00 PM
Creation date
6/23/2020 6:56:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 EVR PHASE II UPGRADE
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2008 EVR PHASE II UPGRADE.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping information continued- <br /> Check <br /> Box Code <br /> Section <br /> 25290.1(c)(1) Piping compatible with material intended to be stored. <br /> 25290.2(c)(1) <br /> 23 CCR Design and construction of piping approved by independent testing organization(e.g.UL). <br /> 2631 b <br /> A- Piping,including vent lines,sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br /> HSC <br /> 25290.1(k) <br /> 25290.20&0) Vapor recovery,fill riser,and vent line pipin2 are secondaril contained. t 1 <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> Check <br /> Box Code �� <br /> Section .� <br /> 23 CCR Overspill containment having 'nimum capacity of 5 gallons provided ateh j Il location. <br /> 2635(6) Manufacturer . Model `s �� <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> Restrict delivery of flow to the tank at least 30 minutes before the tank overfills,provided the <br /> restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an audible <br /> 23 CCR alarm at least five minutes before the tank overfills <br /> 2635(6)(2) <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. i <br /> Manufacturer ` Modei 1 1 <br /> H. CORROSION PROTECTION: <br /> Check <br /> BoxCode <br /> Section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: Steel with cathodic protection or impressed current <br /> 23 CCR Steel isolated from contact with backfill <br /> 2636(b) <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: Sacrificial Anode <br /> 23 CCR Steel tank with field inst led cathodic protection or impressed <br /> 2635(a)(2) <br /> current � <br /> Tie-downs,when used,constructe of non-corrosive material or coated steel. <br /> Revised 061108 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.