My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 1:45:25 PM
Creation date
6/23/2020 6:57:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\J\JACK TONE\1501\PR0505264\FINAL JUDGMENT ON CONSENT 09-29-08.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
four inches including one sensor raised approximately three feet above the under dispenser <br /> containment. <br /> CCR 2712(b) — Maintenance and monitoring records. Written monitoring and maintenance <br /> records shall be maintained on-site or off-site at a readily available location, if approved by the local <br /> agency, for at least 3 years, 6 %2 years for cathodic protection maintenance records and 5 years for <br /> written performance claims pertaining to release detection systems, and calibration and maintenance <br /> records for such systems. <br /> Documentation regarding the cause of alarms and any the corrective action taken were <br /> not available for review. <br /> CCR 2636(f)(4) — Annual line tightness test. Monitoring shall be conducted on all underground <br /> pressurized piping with secondary containment at least annually at a pressure designated by the <br /> equipment manufacturer, provided that the method is capable of detecting a minimum release <br /> equivalent to 0.1 gallon per hour defined at 150 percent of the normal operating pressure of the <br /> product piping system at the test pressure with at least a 95 percent probability of detection and not <br /> more than a 5 percent probability of false alarm. <br /> Line tightness test was not performed. <br /> CCR 2638(a)—Annual certification of monitoring equipment. All monitoring equipment used to <br /> satisfy the requirement of this article shall be installed, calibrated, operated and maintained in <br /> accordance with manufacturer's instructions, and certified every 12 months for operability, proper <br /> operating condition, and proper calibration. <br /> There was no monitoring certification performed in 2003 or 2005. It has been scheduled <br /> for May 26,2005. <br /> CCR 2662 — Requirements for upgrading UST. Before upgrading an underground storage tank <br /> system, the owner or operator shall demonstrate to the satisfaction of the local agency that the <br /> conditions and requirements specified in subsection 2660(k)will be met. <br /> The 87-RUL and 91-SUL spill containers were replaced in 2002 (exact date unknown) <br /> without notification to the department. Inspections were not done at the time of the <br /> retrofit but inspections have been made since. <br /> Y. ADD111ONAL ATTACHMENTS <br /> A copy of the file will be sent to the District Attorney's office upon completion of duplication. <br /> Attachment 1-Notice to abate—March 9,2004 <br /> Attachment 2-Permit application to install overfill prevention—March 9,2004 <br /> Attachment 3-Inspection report with pictures—March 26,2004 <br /> Attachment 4-Invoice from Elite IV regarding UDC clean-up—March 26,2004 <br /> Attachment 5-Permit application to install spill buckets—March 26,2004 <br /> Attachment 6-Letter of contradiction to SJAPCD—EHD received on May 6,2004 <br /> Attachment 7-Letter to facility to schedule testing—April 6,2005 <br /> Attachment 8-Copy of the D.O.notification form—December 31,2004 <br /> Attachment 9-E-mail to facility regarding site visit—May 11,2005 <br /> Attachment 10-Copy of D.O. inspection reports for January,2005 to May,2005—May 12,2005 <br /> Attachment 11-File Narrative-Updated <br /> 8 <br />